Development of positively charged polyamide reverse osmosis membrane via polyethyleneimine spray coating for enhanced radionuclide rejection in water treatment

• Enhancing cation interaction by reducing negative charge using PEI . • Increased rejection rates for Cs + , Cd 2+ , and Cr 3+ by 14.89 %, 17.39 %, and 4.12 %, respectively. • The membrane demonstrated improved 24-hour stability and antifouling properties. • The interactions between the PEI modifying layer and PA are elucidated. While reverse osmosis (RO) is effective for treating radionuclide-contaminated wastewater, it is confronted by some limitations including membrane fouling and limited rejection towards ions with relatively small hydrated radii like Cs + . In this study, surface modification of PA TFC membranes is explored for the improvement of radionuclide rejection efficiency. A convenient spray coating method was employed to introduce a polyethyleneimine (PEI) layer of different concentrations on the membrane surface, thereby rendering desired positive surface charges for efficient rejection of Cs + , Cd 2+ , and Cr 3+ ions. The modified membranes were characterized in terms of their morphological changes, surface charge density, long-term stability and fouling resistance. The Cs + , Cd 2+ and Cr 3+ ion rejection of the optimized membrane, TFC membrane coated with 0.1 mg/l PEI, was significantly improved by 14.89 %, 17.39 % and 4.12 %, respectively. The surface features of the membrane remained unchanged over the 24-hour filtration testing, suggesting the stability of the coating layer. The findings of this study suggest that PEI spray coating can serve as a promising approach to improve radionuclide ion removal from aqueous systems and represents a promising approach for membrane-based wastewater treatment.

Authors

Institutions

Publication Details

Journal
Journal of the Taiwan Institute of Chemical Engineers
Published
2025-04-12
DOI
https://doi.org/10.1016/j.jtice.2025.106135
Citations
6
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
4.90

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of positively charged polyamide reverse osmosis membrane via polyethyleneimine spray coating for enhanced radionuclide rejection in water treatment

Ahmad Fauzi Ismail, Muhammad ’Adli Nor Azman, Pei Sean Goh, Muhammad Hafizuddin Hazaraimi et al.
6 citations
Journal of the Taiwan Institute of Chemical Engineers
Membrane Separation Technologies
4.90
article

Development of positively charged polyamide reverse osmosis membrane via polyethyleneimine spray coating for enhanced radionuclide rejection in water treatment

Ahmad Fauzi Ismail, Muhammad ’Adli Nor Azman, Pei Sean Goh, Muhammad Hafizuddin Hazaraimi, Khairulnadzmi Jamaluddin, Ahmad Syazwan Sahril, Nor Akalili Ahmad
article en
6 citations

Abstract

• Enhancing cation interaction by reducing negative charge using PEI . • Increased rejection rates for Cs + , Cd 2+ , and Cr 3+ by 14.89 %, 17.39 %, and 4.12 %, respectively. • The membrane demonstrated improved 24-hour stability and antifouling properties. • The interactions between the PEI modifying layer and PA are elucidated. While reverse osmosis (RO) is effective for treating radionuclide-contaminated wastewater, it is confronted by some limitations including membrane fouling and limited rejection towards ions with relatively small hydrated radii like Cs + . In this study, surface modification of PA TFC membranes is explored for the improvement of radionuclide rejection efficiency. A convenient spray coating method was employed to introduce a polyethyleneimine (PEI) layer of different concentrations on the membrane surface, thereby rendering desired positive surface charges for efficient rejection of Cs + , Cd 2+ , and Cr 3+ ions. The modified membranes were characterized in terms of their morphological changes, surface charge density, long-term stability and fouling resistance. The Cs + , Cd 2+ and Cr 3+ ion rejection of the optimized membrane, TFC membrane coated with 0.1 mg/l PEI, was significantly improved by 14.89 %, 17.39 % and 4.12 %, respectively. The surface features of the membrane remained unchanged over the 24-hour filtration testing, suggesting the stability of the coating layer. The findings of this study suggest that PEI spray coating can serve as a promising approach to improve radionuclide ion removal from aqueous systems and represents a promising approach for membrane-based wastewater treatment.

Journal of the Taiwan Institute of Chemical EngineersVol. 172
Sultan Idris Education University (MY), University of Technology Malaysia (MY)
Ministry of Higher Education, Malaysia
Clean water and sanitation
Openalex Percentile: Top 6%
Membrane Separation Technologies
4.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.