Sauter mean diameter and drop size distribution behavior in a horizontal vertical pulsed sieve plate column

The L-shaped pulsed sieve-plate column (LPSPC) was introduced by Akhgar et al. to improve the efficiency of horizontal columns. It combined vertical and horizontal columns to enhancing efficiency, reducing height and increasing capacity through suction forces at the connection point. Droplet size is crucial for hydrodynamics and mass transfer in extraction columns, affecting interfacial area and overall performance. The Sauter mean diameter (SMD) and drop size distribution (DSD) are key design parameters in LPSPCs. The behavior of SMD and DSD was investigated in an LPSPC for four chemical systems, including water-kerosene, 17% nitric acid-5% TBP/kerosene (v/v), 17% nitric acid-15% TBP/kerosene (v/v) and 17% nitric acid-30% TBP/kerosene (v/v). The influence of the operating parameters such as pulsation intensity and flow rate of dispersed and continuous phases on SMD and DSD were evaluated. Additionally, the effect of interfacial tension and the percentage of TBP in the dispersed phase on SMD were investigated. Using the experimental results, semi-empirical correlations were obtained for prediction of SMD, which proved to be in great agreement with the experimental data. The average absolute relative error (AARE) of these correlations was 6.95% and 8.29% for the horizontal and vertical sections, respectively. Furthermore, new correlations were presented for prediction of DSD based on the four models of distribution functions. The AARE values of α and β parameters for each of the normal, log-normal, Weibull, and gamma functions were about 3.40-9.60, 11.52-17.65, 2.62-16.00, and 29.09-38.93%, respectively. According to the results, normal, Weibull and log-normal models were acceptable, in order.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-11
DOI
https://doi.org/10.1038/s41598-025-96685-1
Citations
3
Primary Topic
Fluid Dynamics and Mixing
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sauter mean diameter and drop size distribution behavior in a horizontal vertical pulsed sieve plate column

Fatemeh Ardestani, Ahad Ghaemi
3 citations
Scientific Reports
Fluid Dynamics and Mixing
2.02
article

Sauter mean diameter and drop size distribution behavior in a horizontal vertical pulsed sieve plate column

Fatemeh Ardestani, Ahad Ghaemi
article en
3 citations

Abstract

The L-shaped pulsed sieve-plate column (LPSPC) was introduced by Akhgar et al. to improve the efficiency of horizontal columns. It combined vertical and horizontal columns to enhancing efficiency, reducing height and increasing capacity through suction forces at the connection point. Droplet size is crucial for hydrodynamics and mass transfer in extraction columns, affecting interfacial area and overall performance. The Sauter mean diameter (SMD) and drop size distribution (DSD) are key design parameters in LPSPCs. The behavior of SMD and DSD was investigated in an LPSPC for four chemical systems, including water-kerosene, 17% nitric acid-5% TBP/kerosene (v/v), 17% nitric acid-15% TBP/kerosene (v/v) and 17% nitric acid-30% TBP/kerosene (v/v). The influence of the operating parameters such as pulsation intensity and flow rate of dispersed and continuous phases on SMD and DSD were evaluated. Additionally, the effect of interfacial tension and the percentage of TBP in the dispersed phase on SMD were investigated. Using the experimental results, semi-empirical correlations were obtained for prediction of SMD, which proved to be in great agreement with the experimental data. The average absolute relative error (AARE) of these correlations was 6.95% and 8.29% for the horizontal and vertical sections, respectively. Furthermore, new correlations were presented for prediction of DSD based on the four models of distribution functions. The AARE values of α and β parameters for each of the normal, log-normal, Weibull, and gamma functions were about 3.40-9.60, 11.52-17.65, 2.62-16.00, and 29.09-38.93%, respectively. According to the results, normal, Weibull and log-normal models were acceptable, in order.

Scientific ReportsVol. 15(1)
Iran University of Science and Technology (IR)
Clean water and sanitation
Openalex Percentile: Top 15%
Fluid Dynamics and Mixing
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sauter mean diameter and drop size distribution behavior in a horizontal vertical pulsed sieve plate column — Fatemeh Ardestani, Ahad Ghaemi · Scientific Reports (2025) | TGRS Research Map | TGRS