Enhancing The Performance of Beam-Column Joint Using Artificial Fibers

In recent seismic events, numerous moment-resisting reinforced concrete frame buildings have experienced collapse due to shear failure at beam-column connections. Evidence from these earthquakes indicates that compromised beam-column joints significantly undermine the overall structural integrity of the buildings. The overall ductility of structures is also reduced considerably by brittle joint shear failure; As a result, dangerous failure mechanisms emerge. A variety of techniques have been developed to strengthen beam-column joints. Steel and concrete jacketing are examples of these techniques. A novel technique for enhancing structural components has been recognized for over a decade, utilizing fiber-reinforced polymer (FRP) as externally bonded reinforcement in critical areas of reinforced concrete (RC) elements. This paper investigates the impact of glass fiber-reinforced polymer wrapping on corner beam-column joint frames subjected to ultimate loads. The specimens prepared for this study will measure 700 mm x 700 mm, with a cross-sectional dimension of 200 mm x 100 mm. Twelve concrete specimens will be integrated with glass fiber-reinforced polymer to ensure adequate reinforcement.

Authors

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.54646/sapars.2025.01
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing The Performance of Beam-Column Joint Using Artificial Fibers

R Chitra, D. J. Richards, K. Kiruthiga
3 links
Structural Load-Bearing Analysis
article

Enhancing The Performance of Beam-Column Joint Using Artificial Fibers

R Chitra, D. J. Richards, K. Kiruthiga
article en

Abstract

In recent seismic events, numerous moment-resisting reinforced concrete frame buildings have experienced collapse due to shear failure at beam-column connections. Evidence from these earthquakes indicates that compromised beam-column joints significantly undermine the overall structural integrity of the buildings. The overall ductility of structures is also reduced considerably by brittle joint shear failure; As a result, dangerous failure mechanisms emerge. A variety of techniques have been developed to strengthen beam-column joints. Steel and concrete jacketing are examples of these techniques. A novel technique for enhancing structural components has been recognized for over a decade, utilizing fiber-reinforced polymer (FRP) as externally bonded reinforcement in critical areas of reinforced concrete (RC) elements. This paper investigates the impact of glass fiber-reinforced polymer wrapping on corner beam-column joint frames subjected to ultimate loads. The specimens prepared for this study will measure 700 mm x 700 mm, with a cross-sectional dimension of 200 mm x 100 mm. Twelve concrete specimens will be integrated with glass fiber-reinforced polymer to ensure adequate reinforcement.

Vol. 1(1)
Openalex Percentile: Top 93%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing The Performance of Beam-Column Joint Using Artificial Fibers — R Chitra, D. J. Richards, et al. · (2025) | TGRS Research Map | TGRS