Cadaveric study to analyse the influence of distal radial malunion on muscle control of carpal rotational alignment

Extra-articular distal radial malunion may result in poor functional outcome. This biomechanical study aims to investigate whether changes in the shape of distal radius (length and/or inclination) may influence the muscle control of carpal rotational alignment. Nine cryopreserved cadaveric specimens were used to reproduce six distal radius conditions: (1) unaltered anatomy; (2) 20° dorsal tilt; (3) 20° anterior tilt; (4) 4 mm shortening; (5) 20° anterior tilt and 4 mm shortening; and (6) 20° dorsal tilt and 4 mm shortening. Combined shortening and dorsal tilting of the radius reduced the supination effect of abductor pollicis longus and extensor carpi radialis longus on the distal carpal row, whereas combined shortening and anterior tilting prompted pronation of the distal row when all muscles were contracted. This study provides evidence that distal radial malunion may alter muscular control of carpal rotational alignment.

Authors

Institutions

Publication Details

Journal
Journal of Hand Surgery (European Volume)
Published
2025-04-12
DOI
https://doi.org/10.1177/17531934251330985
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cadaveric study to analyse the influence of distal radial malunion on muscle control of carpal rotational alignment

Mireia Esplugas, Mònica Cos, A. Lluch, Núria Fernández-Noguera et al.
Journal of Hand Surgery (European Volume)
Orthopedic Surgery and Rehabilitation
article

Cadaveric study to analyse the influence of distal radial malunion on muscle control of carpal rotational alignment

Mireia Esplugas, Mònica Cos, A. Lluch, Núria Fernández-Noguera, Manuel Llusá-Pérez
article en

Abstract

Extra-articular distal radial malunion may result in poor functional outcome. This biomechanical study aims to investigate whether changes in the shape of distal radius (length and/or inclination) may influence the muscle control of carpal rotational alignment. Nine cryopreserved cadaveric specimens were used to reproduce six distal radius conditions: (1) unaltered anatomy; (2) 20° dorsal tilt; (3) 20° anterior tilt; (4) 4 mm shortening; (5) 20° anterior tilt and 4 mm shortening; and (6) 20° dorsal tilt and 4 mm shortening. Combined shortening and dorsal tilting of the radius reduced the supination effect of abductor pollicis longus and extensor carpi radialis longus on the distal carpal row, whereas combined shortening and anterior tilting prompted pronation of the distal row when all muscles were contracted. This study provides evidence that distal radial malunion may alter muscular control of carpal rotational alignment.

Journal of Hand Surgery (European Volume)Vol. 50(9)
Clínica Girona (ES), Vall d'Hebron Hospital Universitari (ES), Institut Kaplan (ES), Hospital Universitari de Girona Doctor Josep Trueta (ES), Universitat de Barcelona (ES)
No poverty
Openalex Percentile: Top 87%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cadaveric study to analyse the influence of distal radial malunion on muscle control of carpal rotational alignment — Mireia Esplugas, Mònica Cos, et al. · Journal of Hand Surgery (European Volume) (2025) | TGRS Research Map | TGRS