Rapid Determination of 25‐Hydroxyvitamin D <sub>3</sub> and 24,25‐Dihydroxyvitamin D <sub>3</sub> in Human Urine Based on Polystyrene/Graphene Oxide Packed‐Fibers Solid‐Phase Extraction Coupled With High‐Performance Liquid Chromatography and Atmosphe

Vitamin D plays a crucial role in skeletal metabolism and is implicated in various diseases. Several studies have indicated that human vitamin D status can be evaluated through urine hydroxyvitamin D levels, in addition to plasma hydroxyvitamin D concentrations. In this study, we developed a novel method for the detection of trace amounts of 25-hydroxyvitamin D<sub>3</sub> [25(OH)D<sub>3</sub>] and 24,25-dihydroxyvitamin D<sub>3</sub> [24,25(OH)<sub>2</sub>D<sub>3</sub>] in urine. This method is based on high-performance liquid chromatography coupled with atmospheric pressure chemical ion source-tandem mass spectrometry, integrated with packed-fibers solid-phase extraction. The composite polystyrene/graphene oxide (PS/GO) nanofibers were synthesized as the sorbent for concentrating 25(OH)D<sub>3</sub> and 24,25(OH)<sub>2</sub>D<sub>3</sub>, achieving a twentyfold increase in sensitivity when analyzing human urine samples. Fourier-transform infrared spectroscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy mapping analysis were employed to characterize GO, PS, and PS/GO. The results indicated that the composite nanofibers were successfully synthesized. In addition, we investigated the relationship between the extraction performance of the fibers and the electrospinning process at varying flow rates of spinning solution through morphological studies and Brunauer-Emmett-Teller surface area analysis. During the extraction process, purification, concentration, and desorption were accomplished within a single step. The established method demonstrated excellent sensitivity and efficiency. Under optimal conditions, limits of detection (signal-to-noise ratio = 3) were found to be 0.33 ng/mL for 25(OH)D<sub>3</sub> and 0.19 ng/mL for 24,25(OH)<sub>2</sub>D<sub>3</sub>; furthermore, linearity was deemed acceptable across urine samples. Recovery rates ranged from 89.5% to 109.7% for 25(OH)D<sub>3</sub> and from 90.3% to 103.1% for 24,25(OH)<sub>2</sub>D<sub>3</sub>, respectively.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2025-04-01
DOI
https://doi.org/10.1002/jssc.70130
Primary Topic
Vitamin D Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Determination of 25‐Hydroxyvitamin D 3 and 24,25‐Dihydroxyvitamin D 3 in Human Urine Based on Polystyrene/Graphene Oxide Packed‐Fibers Solid‐Phase Extraction Coupled With High‐Performance Liquid Chromatography and Atmosphe

Guozhe Deng, Min Zhou, Geng Li, Qing Han et al.
Journal of Separation Science
Vitamin D Research Studies
article

Rapid Determination of 25‐Hydroxyvitamin D 3 and 24,25‐Dihydroxyvitamin D 3 in Human Urine Based on Polystyrene/Graphene Oxide Packed‐Fibers Solid‐Phase Extraction Coupled With High‐Performance Liquid Chromatography and Atmosphe

Guozhe Deng, Min Zhou, Geng Li, Qing Han, Feng Guo, Xuejun Kang
article en

Abstract

Vitamin D plays a crucial role in skeletal metabolism and is implicated in various diseases. Several studies have indicated that human vitamin D status can be evaluated through urine hydroxyvitamin D levels, in addition to plasma hydroxyvitamin D concentrations. In this study, we developed a novel method for the detection of trace amounts of 25-hydroxyvitamin D<sub>3</sub> [25(OH)D<sub>3</sub>] and 24,25-dihydroxyvitamin D<sub>3</sub> [24,25(OH)<sub>2</sub>D<sub>3</sub>] in urine. This method is based on high-performance liquid chromatography coupled with atmospheric pressure chemical ion source-tandem mass spectrometry, integrated with packed-fibers solid-phase extraction. The composite polystyrene/graphene oxide (PS/GO) nanofibers were synthesized as the sorbent for concentrating 25(OH)D<sub>3</sub> and 24,25(OH)<sub>2</sub>D<sub>3</sub>, achieving a twentyfold increase in sensitivity when analyzing human urine samples. Fourier-transform infrared spectroscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy mapping analysis were employed to characterize GO, PS, and PS/GO. The results indicated that the composite nanofibers were successfully synthesized. In addition, we investigated the relationship between the extraction performance of the fibers and the electrospinning process at varying flow rates of spinning solution through morphological studies and Brunauer-Emmett-Teller surface area analysis. During the extraction process, purification, concentration, and desorption were accomplished within a single step. The established method demonstrated excellent sensitivity and efficiency. Under optimal conditions, limits of detection (signal-to-noise ratio = 3) were found to be 0.33 ng/mL for 25(OH)D<sub>3</sub> and 0.19 ng/mL for 24,25(OH)<sub>2</sub>D<sub>3</sub>; furthermore, linearity was deemed acceptable across urine samples. Recovery rates ranged from 89.5% to 109.7% for 25(OH)D<sub>3</sub> and from 90.3% to 103.1% for 24,25(OH)<sub>2</sub>D<sub>3</sub>, respectively.

Journal of Separation ScienceVol. 48(4)
Jiangsu Food and Pharmaceutical Science College (CN), Southeast University (CN)
Openalex Percentile: Top 89%
Vitamin D Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.