Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns , time resolutions of around 50 ps have been achieved.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-04-12
DOI
https://doi.org/10.1016/j.nima.2025.170496
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

M. Lisowska, A. Kallitsopoulou, Emmanuel Scorsone, F. Brunbauer et al.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Particle Detector Development and Performance
article

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

M. Lisowska, A. Kallitsopoulou, Emmanuel Scorsone, F. Brunbauer, E. Picatoste Olloqui, Xu Wang, M. Pomorski, R. Manera Escalero, M. Lupberger, M. van Stenis, L. Ropelewski, D. Janssens, A. Sanuy, R. Ballabriga, Z. Zhang, G. Fanourakis, S. N. White, D. Fiorina, Y. Angelis, G. Orlandini, Jianbei Liu, K. Gnanvo, Y. Tsipolitis, K.J. Flöthner, J. Alozy, T. Papaevangelou, Marinko Kovačić, H. Müller, F.J. Iguaz, Jaydeep Datta, Markus Piller, B. Kross, Y. Meng, L. Scharenberg, M. Campbell, R. Veenhof, A. Mariscal-Castilla, P. Vitulo, Thomas Schneider, Yi Zhou, J. M. Fernandez-tenllado Arribas, I. M. Maniatis, J. Mauricio, D. Gascón, R. De Oliveira, K. Dehmelt, E. Oliveri, M. Gallinaro, I. Vai, M. Brunoldi, L. Sohl, S. Gomez Fernandez, F. García, A. Utrobicic, D. Sampsonidis, J. Bortfeldt, Anand Pandey, S.E. Tzamarias, W. Xi, I. Giomataris, J. McKisson, P. Legou, S. Aune
article en

Abstract

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns , time resolutions of around 50 ps have been achieved.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1076
University of Helsinki (FI), University of Bonn (DE), Aristotle University of Thessaloniki (GR), University of Pavia (IT), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Université Paris-Saclay (FR), LIP - Laboratory of Instrumentation and Experimental Particle Physics (PT), Helsinki Institute of Physics (FI), Thomas Jefferson National Accelerator Facility (US), Istituto Nazionale di Fisica Nucleare, Sezione di Pavia (IT), CEA Paris-Saclay (FR), Institute of Nuclear and Particle Physics (GR), Institut de Recherche sur les Lois Fondamentales de l'Univers (FR), Stony Brook University (US), European Organization for Nuclear Research (CH), Universitat de Barcelona (ES), Ludwig-Maximilians-Universität München (DE)
U.S. Department of Energy, CERN, European Commission, National Natural Science Foundation of China, Commissariat à l'Énergie Atomique et aux Énergies Alternatives, Université Paris-Saclay, Office of Science, HORIZON EUROPE Framework Programme, Fundação para a Ciência e a Tecnologia, Nuclear Physics
Affordable and clean energy
Openalex Percentile: Top 96%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.