Determination of Typical Values for Pediatric Head CT Scan at Universitas Andalas Hospital

The utilization of X-rays in the Computed Tomography Scaner (CT scan) modality has proliferated for diagnostic purposes. CT scans deliver higher doses than other modalities, consequently protecting patients from excessive radiation doses is necessary by increasing optimization efforts in patients, especially pediatric patients. This research aims to determine the typical value and analyze the correlation of age, body mass, and exposure factor (mAs) to Computed Tomography Dose Index Volume (CTDIVol) and Dose Length Product (DLP). The typical dose value was obtained from the median value (Q2) using data derived from pediatric patients undergoing a head CT scan with a total of 33 patients at Universitas Andalas Hospital, with a correlation determined using a linearity test. The results obtained were the typical value for CTDIVol of 31.1 mGy and DLP of 793.3 mGy.cm. There is a moderate correlation between age and CTDIVol and DLP values, a high correlation between body mass and CTDIVol and DLP values, and a very high correlation between the exposure factor (mAs) and CTDIVol and DLP values.

Authors

Publication Details

Journal
Atom Indonesia
Published
2025-03-13
DOI
https://doi.org/10.55981/aij.2025.1517
Primary Topic
Public Health and Nutrition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Typical Values for Pediatric Head CT Scan at Universitas Andalas Hospital

Dian Milvita, Ramacos Fardela, Ida Bagus Gede Putra Pratama, Rani Delvihardini et al.
Atom Indonesia
Public Health and Nutrition
article

Determination of Typical Values for Pediatric Head CT Scan at Universitas Andalas Hospital

Dian Milvita, Ramacos Fardela, Ida Bagus Gede Putra Pratama, Rani Delvihardini, Amel Oktavia
article en

Abstract

The utilization of X-rays in the Computed Tomography Scaner (CT scan) modality has proliferated for diagnostic purposes. CT scans deliver higher doses than other modalities, consequently protecting patients from excessive radiation doses is necessary by increasing optimization efforts in patients, especially pediatric patients. This research aims to determine the typical value and analyze the correlation of age, body mass, and exposure factor (mAs) to Computed Tomography Dose Index Volume (CTDIVol) and Dose Length Product (DLP). The typical dose value was obtained from the median value (Q2) using data derived from pediatric patients undergoing a head CT scan with a total of 33 patients at Universitas Andalas Hospital, with a correlation determined using a linearity test. The results obtained were the typical value for CTDIVol of 31.1 mGy and DLP of 793.3 mGy.cm. There is a moderate correlation between age and CTDIVol and DLP values, a high correlation between body mass and CTDIVol and DLP values, and a very high correlation between the exposure factor (mAs) and CTDIVol and DLP values.

Atom IndonesiaVol. 51(1)
Openalex Percentile: Top 90%
Public Health and Nutrition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of Typical Values for Pediatric Head CT Scan at Universitas Andalas Hospital — Dian Milvita, Ramacos Fardela, et al. · Atom Indonesia (2025) | TGRS Research Map | TGRS