Source Identification Performance of Plastic Scintillator Ranging from 100–1300 keV: Assessment Through Monte Carlo Code and Experimental Validation

Current plastic detectors need improvement in efficiency and accuracy, to enhance reliability. Simulation offers a cost-effective approach to accelerate detector development, yet its effectiveness relies on the reliability of the simulations used. Therefore, validating these simulations is crucial to ensure they accurately reflect actual scenarios and yield reliable results. This study employs the Monte Carlo approach to estimate the performance and efficiency of a plastic detector exposed to radiation sources within the 100–1300 keV energy range. The plastic detector (50 mm x 3 mm) was simulated using MCNP with Gaussian Energy Broadening (GEB) correction applied to capture detector response. Simulated data were then compared against experimental measurements to validate the model. This work aims to confirm that simulation results align with empirical data, ensuring theoretical models accurately represent physical phenomena. The study highlights both the limitations and strengths of simulation codes, leading to more efficient research through validated models. Notably, an 8.04 % deviation was observed at 662 keV for 137Cs, demonstrating a strong correlation between simulated and experimental results and confirming the model’s accuracy and reliability.

Authors

Publication Details

Journal
Atom Indonesia
Published
2025-02-12
DOI
https://doi.org/10.55981/aij.2025.1401
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Source Identification Performance of Plastic Scintillator Ranging from 100–1300 keV: Assessment Through Monte Carlo Code and Experimental Validation

K Kasmudin, Hana Subhiyah, A. Jamil, Hafni Lissa Nuri et al.
Atom Indonesia
Radiation Dose and Imaging
article

Source Identification Performance of Plastic Scintillator Ranging from 100–1300 keV: Assessment Through Monte Carlo Code and Experimental Validation

K Kasmudin, Hana Subhiyah, A. Jamil, Hafni Lissa Nuri, Moien A. Omar, M. Pancoko, G. E. Putro
article en

Abstract

Current plastic detectors need improvement in efficiency and accuracy, to enhance reliability. Simulation offers a cost-effective approach to accelerate detector development, yet its effectiveness relies on the reliability of the simulations used. Therefore, validating these simulations is crucial to ensure they accurately reflect actual scenarios and yield reliable results. This study employs the Monte Carlo approach to estimate the performance and efficiency of a plastic detector exposed to radiation sources within the 100–1300 keV energy range. The plastic detector (50 mm x 3 mm) was simulated using MCNP with Gaussian Energy Broadening (GEB) correction applied to capture detector response. Simulated data were then compared against experimental measurements to validate the model. This work aims to confirm that simulation results align with empirical data, ensuring theoretical models accurately represent physical phenomena. The study highlights both the limitations and strengths of simulation codes, leading to more efficient research through validated models. Notably, an 8.04 % deviation was observed at 662 keV for 137Cs, demonstrating a strong correlation between simulated and experimental results and confirming the model’s accuracy and reliability.

Atom IndonesiaVol. 51(1)
Openalex Percentile: Top 89%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Source Identification Performance of Plastic Scintillator Ranging from 100–1300 keV: Assessment Through Monte Carlo Code and Experimental Validation — K Kasmudin, Hana Subhiyah, et al. · Atom Indonesia (2025) | TGRS Research Map | TGRS