Numerical Simulations of Shaking Table Tests of Metro‐Induced Vertical Vibrations of Interstory‐Isolated, Base‐Isolated, and Fixed‐Base Structures

Metro networks have been extensively developed in large cities to satisfy traffic demands. Adjacent to subways, there has been an increasing construction of fixed‐base, base‐isolated, and interstory‐isolated buildings on metro depots. Notably, metro‐induced environmental vibrations have led to vibrations in buildings, thus affecting human health and the regular operation of sensitive equipment. Numerical simulations are considered a valuable method for assessing building vibrations. However, research on a generalized numerical simulation strategy for simulating the metro‐induced vibrations of the abovementioned three types of buildings remains rare. Hence, this study recommends a generalized numerical simulation strategy and validates it through the comparison between the results of shaking table tests. The acceleration time histories of floor, distributions of the acceleration at different positions on the slab and along the height of the building, and one‐third octave band vertical acceleration levels were accurately simulated for the three structures. Meanwhile, the simulation accuracies of three types of damping models were discussed. The relative differences between the simulated and experimental maximum acceleration amplification coefficients and one‐third octave band vertical acceleration levels were both less than 4.2%. Furthermore, the influences of the mesh sizes of the elements for the slabs and the parameters of the Rayleigh damping model on the simulated results were investigated. The recommended simulation strategy can contribute to further investigation of the metro‐induced vertical vibration assessment of different types of structures.

Authors

Institutions

Publication Details

Journal
Structural Control and Health Monitoring
Published
2025-01-01
DOI
https://doi.org/10.1155/stc/8105608
Citations
2
Primary Topic
Railway Engineering and Dynamics
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Simulations of Shaking Table Tests of Metro‐Induced Vertical Vibrations of Interstory‐Isolated, Base‐Isolated, and Fixed‐Base Structures

Cantian Yang, Linlin Xie, Xinyu Wang, Tao Wang et al.
2 citations
Structural Control and Health Monitoring
Railway Engineering and Dynamics
1.43
article

Numerical Simulations of Shaking Table Tests of Metro‐Induced Vertical Vibrations of Interstory‐Isolated, Base‐Isolated, and Fixed‐Base Structures

Cantian Yang, Linlin Xie, Xinyu Wang, Tao Wang, Aiqun Li
article en
2 citations

Abstract

Metro networks have been extensively developed in large cities to satisfy traffic demands. Adjacent to subways, there has been an increasing construction of fixed‐base, base‐isolated, and interstory‐isolated buildings on metro depots. Notably, metro‐induced environmental vibrations have led to vibrations in buildings, thus affecting human health and the regular operation of sensitive equipment. Numerical simulations are considered a valuable method for assessing building vibrations. However, research on a generalized numerical simulation strategy for simulating the metro‐induced vibrations of the abovementioned three types of buildings remains rare. Hence, this study recommends a generalized numerical simulation strategy and validates it through the comparison between the results of shaking table tests. The acceleration time histories of floor, distributions of the acceleration at different positions on the slab and along the height of the building, and one‐third octave band vertical acceleration levels were accurately simulated for the three structures. Meanwhile, the simulation accuracies of three types of damping models were discussed. The relative differences between the simulated and experimental maximum acceleration amplification coefficients and one‐third octave band vertical acceleration levels were both less than 4.2%. Furthermore, the influences of the mesh sizes of the elements for the slabs and the parameters of the Rayleigh damping model on the simulated results were investigated. The recommended simulation strategy can contribute to further investigation of the metro‐induced vertical vibration assessment of different types of structures.

Structural Control and Health MonitoringVol. 2025(1)
Beijing University of Civil Engineering and Architecture (CN), China Earthquake Administration (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 21%
Railway Engineering and Dynamics
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.