Artificial neural network-based forecasting of air temperature reduction in a tube bank under electric field

This study aims to investigate the potential of Artificial Neural Networks (ANN) in predicting the heat transfer behavior of air as it flows through a tube bank with low temperature and operates under an electric field. To date, no previous studies have applied ANN for predicting heat transfer characteristics under these specific conditions. ANN is employed to address the complexities in heat exchanger systems, as it effectively handles non-linear relationships and multiple variables, allowing for accurate predictions of air temperature and heat transfer rates across each column in the tube bank. The tube bank used in this study consisted of 10 rows of tubes with a diameter of 15 mm, a pitch ratio of 1–4, an inlet air temperature of 40–45 °C, a surface temperature of 30–40 °C, an air velocity of 0.1–0.25 m/s, and high voltage DC ranging from 7 to 15 kV DC . The heat transfer rate and outlet air temperature were the output results. The study evaluated the optimal ANN model structure, including the appropriate number of neurons in the hidden layer, the number of epochs, and the suitable activation function for predicting heat transfer performance under an electric field. The combination of the Sigmoid-Purelin activation function with 8 neurons and 30 epochs proved to be the most suitable for this study. The ANN model demonstrated exceptional accuracy in predicting performance across a variety of conditions for each row in the tube bank. Finally, correlations were developed between the temperature ratio and the maximum Reynolds number at different S/D ratios, both with and without the electric field. The results computed using ANN closely matched theoretical heat transfer predictions, with R-squared values greater than 0.99 and MSE less than 0.000025. Furthermore, when the ANN model was tested beyond the training data conditions, the predicted results still exhibited a high level of accuracy compared to the theoretical heat transfer calculations.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-04-11
DOI
https://doi.org/10.1016/j.csite.2025.106086
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial neural network-based forecasting of air temperature reduction in a tube bank under electric field

Tanongkiat Kiatsiriroat, Attakorn Asanakham, Thoranis Deethayat, E.L. Tang
Case Studies in Thermal Engineering
Power Transformer Diagnostics and Insulation
article

Artificial neural network-based forecasting of air temperature reduction in a tube bank under electric field

Tanongkiat Kiatsiriroat, Attakorn Asanakham, Thoranis Deethayat, E.L. Tang
article en

Abstract

This study aims to investigate the potential of Artificial Neural Networks (ANN) in predicting the heat transfer behavior of air as it flows through a tube bank with low temperature and operates under an electric field. To date, no previous studies have applied ANN for predicting heat transfer characteristics under these specific conditions. ANN is employed to address the complexities in heat exchanger systems, as it effectively handles non-linear relationships and multiple variables, allowing for accurate predictions of air temperature and heat transfer rates across each column in the tube bank. The tube bank used in this study consisted of 10 rows of tubes with a diameter of 15 mm, a pitch ratio of 1–4, an inlet air temperature of 40–45 °C, a surface temperature of 30–40 °C, an air velocity of 0.1–0.25 m/s, and high voltage DC ranging from 7 to 15 kV DC . The heat transfer rate and outlet air temperature were the output results. The study evaluated the optimal ANN model structure, including the appropriate number of neurons in the hidden layer, the number of epochs, and the suitable activation function for predicting heat transfer performance under an electric field. The combination of the Sigmoid-Purelin activation function with 8 neurons and 30 epochs proved to be the most suitable for this study. The ANN model demonstrated exceptional accuracy in predicting performance across a variety of conditions for each row in the tube bank. Finally, correlations were developed between the temperature ratio and the maximum Reynolds number at different S/D ratios, both with and without the electric field. The results computed using ANN closely matched theoretical heat transfer predictions, with R-squared values greater than 0.99 and MSE less than 0.000025. Furthermore, when the ANN model was tested beyond the training data conditions, the predicted results still exhibited a high level of accuracy compared to the theoretical heat transfer calculations.

Case Studies in Thermal EngineeringVol. 70
Chiang Mai University (TH)
Affordable and clean energy
Openalex Percentile: Top 94%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.