An electrochemical microfluidic sensor based on a Cu<sub>2</sub>O-GNP nanocomposite integrated hydrogel for nitrite detection in food samples
The integration of a nanocomposite composed of cuprous oxide-graphene nanoplatelet hydrogel (Cu<sub>2</sub>O-GNP hydrogel) has been investigated as an electrochemical interface for nitrite (NO<sub>2</sub><sup>-</sup>) detection. The nanocomposite hydrogel was prepared through the sonochemical technique and characterized by Field Emission Scanning Electron Microscopy (FE-SEM), EDX (energy dispersive X-ray analysis), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). Electrochemical performance was further evaluated using Electrochemical Impedance Spectroscopy (EIS), Cyclic Voltammetry (CV), and Differential Pulse Voltammetry (DPV). Cu<sub>2</sub>O provides a catalytic active site that lower the activation energy for NO<sub>2</sub><sup>-</sup> oxidation, while GNPs enhance the electrode conductivity and increase the surface area for superior electron transfer. Additionally, a PDMS-based microfluidic device was developed and integrated with an electrochemical detection system, enabling continuous and real-time monitoring of NO<sub>2</sub><sup>-</sup>. A syringe pump was used to maintain a stable NO<sub>2</sub><sup>-</sup> solution flow through the microfluidic channels at a 10 μL per min flow rate, ensuring sufficient diffusion of NO<sub>2</sub><sup>-</sup> ions to the electrode surface, and preventing excess analyte accumulation that could lead to signal distortion. The integrated microfluidic sensor exhibited excellent electrochemical performance, achieving a high sensitivity of 13.97 μA μM<sup>-1</sup> cm<sup>-2</sup> and a low detection limit (LOD) of 0.56 μM, with a linear range of 5-130 μM. Cu<sub>2</sub>O-GNP hydrogel/SPCE exhibited excellent selectivity and reproducibility for NO<sub>2</sub><sup>-</sup> sensing. The developed sensor demonstrated good recovery percentages in sausages, pickled vegetables, and water samples, confirming its suitability for the food industry.
Authors
- Vijayesh Kumar (ORCID: https://orcid.org/0000-0003-4267-0363)
- Deepanshu Bhatt (ORCID: https://orcid.org/0000-0001-7364-2563)
- Ishita Matai (ORCID: https://orcid.org/0000-0003-1698-2515)
- Abhay Sachdev (ORCID: https://orcid.org/0000-0002-2114-8712)
- Deepak Kumar (ORCID: https://orcid.org/0000-0002-0913-3198)
- Deepa Garg
Institutions
- Chandigarh University (IN)
- Central Scientific Instruments Organisation (IN)
- Amity University (AE)
- Academy of Scientific and Innovative Research (IN)
Publication Details
- Journal
- Analytical Methods
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1039/d5ay00144g
- Citations
- 6
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 4.38