Venturi Optimization and Local Pressure Method for Measuring Supercritical CO2 Flow in Downhole

This study is dedicated to exploring and verifying the application of a miniature Venturi sensor for measuring the flowrate of supercritical CO2 and associated gas in downhole environments. With the rapid development of CO2 gas injection technology and Carbon Capture, Utilization, and Storage (CCUS) technology, the demand for accurate measurements of a CO2 and CH4 mixed-medium flowrate is increasing. This paper combines theoretical analysis, simulation design, and experimental validation to determine the optimized structure of a miniature Venturi and to select appropriate pressure sensors, comparing the accuracy of the Local Pressure Method (LPM) and Differential Pressure Method (DPM) in measuring differential pressure. The experiments were conducted using the water flow calibration facility and the gas–liquid two-phase flow rig at Tianjin University, comparing the LPM based on Keller pressure sensors with the DPM based on EJA110A transmitters. The results indicate that the relative error range of the differential pressure measurement is −16.64% to −0.72%, and the absolute error range is −5.19 kPa to −0.24 kPa, meeting the measurement requirements for underground applications. This validates the rational design of the miniature Venturi sensor and the feasibility of using the LPM in downhole.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-04-11
DOI
https://doi.org/10.3390/en18081951
Citations
1
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Venturi Optimization and Local Pressure Method for Measuring Supercritical CO2 Flow in Downhole

Dedong Xue, Wanyou Yang, Lei Kou, Chao Yuan et al.
1 citations
Energies
Flow Measurement and Analysis
0.86
article

Venturi Optimization and Local Pressure Method for Measuring Supercritical CO2 Flow in Downhole

Dedong Xue, Wanyou Yang, Lei Kou, Chao Yuan, Sheng Wang, Zhengyang Chen, Chunfeng Zheng, Shijiao Jia
article en
1 citations

Abstract

This study is dedicated to exploring and verifying the application of a miniature Venturi sensor for measuring the flowrate of supercritical CO2 and associated gas in downhole environments. With the rapid development of CO2 gas injection technology and Carbon Capture, Utilization, and Storage (CCUS) technology, the demand for accurate measurements of a CO2 and CH4 mixed-medium flowrate is increasing. This paper combines theoretical analysis, simulation design, and experimental validation to determine the optimized structure of a miniature Venturi and to select appropriate pressure sensors, comparing the accuracy of the Local Pressure Method (LPM) and Differential Pressure Method (DPM) in measuring differential pressure. The experiments were conducted using the water flow calibration facility and the gas–liquid two-phase flow rig at Tianjin University, comparing the LPM based on Keller pressure sensors with the DPM based on EJA110A transmitters. The results indicate that the relative error range of the differential pressure measurement is −16.64% to −0.72%, and the absolute error range is −5.19 kPa to −0.24 kPa, meeting the measurement requirements for underground applications. This validates the rational design of the miniature Venturi sensor and the feasibility of using the LPM in downhole.

EnergiesVol. 18(8)
Tianjin University (CN)
Openalex Percentile: Top 32%
Flow Measurement and Analysis
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.