A label-free aptasensor based on a fluorescent probe containing styrylbenzothiazole for detection of enrofloxacin

Enrofloxacin (ENR), a third-generation fluoroquinolone antibiotic, poses significant health risks due to potential drug residues in the food chain, necessitating effective monitoring methods. Here, we synthesized a G-quadruplex-targeted fluorescent probe PBTZM containing styrylbenzothiazole. Using this probe, we successfully developed an aptasensor for the detection of ENR by combining it with an ENR aptamer. Under optimal conditions, the aptasensor provided a linear range of 0.001-5 μM and a detection limit of 24.74 nM. In addition, this method showed good performance for ENR detection in river water, milk, serum and urine samples and was further validated by standard HPLC techniques without a significant difference (<i>p</i> > 0.05). It will have great potential in advancing research of quinolone antibiotics and the development of aptamer-based biosensing technologies.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d4ay02265c
Citations
5
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A label-free aptasensor based on a fluorescent probe containing styrylbenzothiazole for detection of enrofloxacin

Xuying Liu, Juntao Niu, Chenchen Li, Dong Wei et al.
5 citations
Analytical Methods
Advanced biosensing and bioanalysis techniques
4.03
article

A label-free aptasensor based on a fluorescent probe containing styrylbenzothiazole for detection of enrofloxacin

Xuying Liu, Juntao Niu, Chenchen Li, Dong Wei, Wei‐Chuang Kong, Yan-Fei Kang
article en
5 citations

Abstract

Enrofloxacin (ENR), a third-generation fluoroquinolone antibiotic, poses significant health risks due to potential drug residues in the food chain, necessitating effective monitoring methods. Here, we synthesized a G-quadruplex-targeted fluorescent probe PBTZM containing styrylbenzothiazole. Using this probe, we successfully developed an aptasensor for the detection of ENR by combining it with an ENR aptamer. Under optimal conditions, the aptasensor provided a linear range of 0.001-5 μM and a detection limit of 24.74 nM. In addition, this method showed good performance for ENR detection in river water, milk, serum and urine samples and was further validated by standard HPLC techniques without a significant difference (<i>p</i> > 0.05). It will have great potential in advancing research of quinolone antibiotics and the development of aptamer-based biosensing technologies.

Analytical MethodsVol. 17(17)
Hebei North University (CN)
Hebei Provincial Department of Bureau of Science and Technology
Openalex Percentile: Top 7%
Advanced biosensing and bioanalysis techniques
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.