Impact of Intertarget Distances on Single-Isocenter Radiotherapy Plans with jaw-Tracking and jaw-Fixed Techniques for Vertebral Metastases

IntroductionMultiple targets with varying distances are common in radiotherapy. Reducing treatment time in the plan design helps minimize patient movement and discomfort during the treatment process. This retrospective study aimed to investigate the impact of varying intertarget distances (ITDs) on the dosimetric differences and delivery efficiency of two single-isocenter techniques.MethodsITDs for 15 patients with dual-site vertebral metastases undergoing volume-modulated arc therapy (VMAT) were modified using Matlab 2019a. Distances of 2, 4, 6, 8, and 10 cm were considered. The VMAT plans were designed with a prescription dose of 40 Gy/20f on Infinity Linac and Monaco 5.40.01. Single-isocenter with jaw tracking (VMAT1) and fixed jaw (VMAT2) were compared in terms of dosimetry and delivery efficiency under different ITDs.ResultsResults showed that both VMAT plans exhibited dosimetric parameters meeting clinical requirements. The conformity index (CI) of VMAT1 plans was smaller than that of VMAT2 at ITD = 4, 6, and 8 cm (P = 0.007, 0.020, and 0.039, respectively), with no significant differences in other planning target volume dosimetry parameters. In terms of delivery efficiency, the treatment time of VMAT1 increased significantly when ITD > 2 cm compared with that at ITD = 2 cm (P = 0.000). Conversely, VMAT2 exhibited no significant change in treatment time at different ITDs (P = 0.073). For ITD = 2 cm, the treatment time of VMAT1 was shorter than that of VMAT2, with a median difference of 77 s. For ITD > 2 cm, the treatment time of VMAT2 was shorter than that of VMAT1, with a median difference ranging from 65 s to 121 s.ConclusionThe experimental results showed that the single-isocenter with jaw tracking is recommended in the planning design when ITDs are less than 2 cm. However, for ITDs greater than 2 cm, the single-isocenter with fixed jaw demonstrates high delivery efficiency.5075.

Authors

Institutions

Publication Details

Journal
Technology in Cancer Research & Treatment
Published
2025-04-11
DOI
https://doi.org/10.1177/15330338251332386
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Intertarget Distances on Single-Isocenter Radiotherapy Plans with jaw-Tracking and jaw-Fixed Techniques for Vertebral Metastases

Dewen Zhang, Xinye Ni, Kai Xie, Huarui Yin et al.
Technology in Cancer Research & Treatment
Advanced Radiotherapy Techniques
article

Impact of Intertarget Distances on Single-Isocenter Radiotherapy Plans with jaw-Tracking and jaw-Fixed Techniques for Vertebral Metastases

Dewen Zhang, Xinye Ni, Kai Xie, Huarui Yin, Ling Xu, Xianfang Yin, Wentong Qiu
article en

Abstract

IntroductionMultiple targets with varying distances are common in radiotherapy. Reducing treatment time in the plan design helps minimize patient movement and discomfort during the treatment process. This retrospective study aimed to investigate the impact of varying intertarget distances (ITDs) on the dosimetric differences and delivery efficiency of two single-isocenter techniques.MethodsITDs for 15 patients with dual-site vertebral metastases undergoing volume-modulated arc therapy (VMAT) were modified using Matlab 2019a. Distances of 2, 4, 6, 8, and 10 cm were considered. The VMAT plans were designed with a prescription dose of 40 Gy/20f on Infinity Linac and Monaco 5.40.01. Single-isocenter with jaw tracking (VMAT1) and fixed jaw (VMAT2) were compared in terms of dosimetry and delivery efficiency under different ITDs.ResultsResults showed that both VMAT plans exhibited dosimetric parameters meeting clinical requirements. The conformity index (CI) of VMAT1 plans was smaller than that of VMAT2 at ITD = 4, 6, and 8 cm (P = 0.007, 0.020, and 0.039, respectively), with no significant differences in other planning target volume dosimetry parameters. In terms of delivery efficiency, the treatment time of VMAT1 increased significantly when ITD > 2 cm compared with that at ITD = 2 cm (P = 0.000). Conversely, VMAT2 exhibited no significant change in treatment time at different ITDs (P = 0.073). For ITD = 2 cm, the treatment time of VMAT1 was shorter than that of VMAT2, with a median difference of 77 s. For ITD > 2 cm, the treatment time of VMAT2 was shorter than that of VMAT1, with a median difference ranging from 65 s to 121 s.ConclusionThe experimental results showed that the single-isocenter with jaw tracking is recommended in the planning design when ITDs are less than 2 cm. However, for ITDs greater than 2 cm, the single-isocenter with fixed jaw demonstrates high delivery efficiency.5075.

Technology in Cancer Research & TreatmentVol. 24
Changzhou No.2 People's Hospital (CN), Nanjing Medical University (CN)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 91%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.