Visual and Structural Differences Between Amblyopic and Non-Amblyopic Eyes in Patients with Unilateral Amblyopia

Background: Amblyopia, define as "lazy eye, a neurodevelopmental disorder, manifests as reduced visual acuity not attributable to structural eye abnormalities. Objective of study: This study investigated visual and structural differences between amblyopic and non-amblyopic eyes in children with unilateral amblyopia, focusing on visual acuity, axial length, and lens thickness. Materials and Methods: Twenty-six pediatric patients (5–10 years old) with untreated unilateral functional amblyopia were recruited. Amblyopia was classified as anisometropic, strabismic, or combined. Corrected distance visual acuity (CDVA) was measured in logMAR units. Axial length, anterior chamber depth, and lens thickness were assessed using non-contact optical biometry. Spherical equivalent refractive error was determined via cycloplegic autorefraction. Paired t-tests were used to compare interocular differences. Results: Amblyopic eyes exhibited significantly reduced CDVA. However, no statistically significant interocular differences were found for spherical equivalent, axial length, anterior chamber depth, or lens thickness (all p > 0.05). Amblyopic eyes showed a trend towards shorter axial lengths (mean difference: -0.27 mm, SD: 0.72), particularly in anisometropic amblyopia (-0.21 mm, SD: 0.85). Anterior chamber depth and lens thickness showed minimal interocular variations across amblyopia types. Conclusion: While amblyopic eyes demonstrated reduced visual acuity, interocular differences in biometric parameters were not statistically significant in this small sample. Trends suggest a potential association between amblyopia and shorter axial length, warranting further investigation with larger, longitudinal studies. This research contributes to understanding the ocular and cortical changes in amblyopia, aiming to refine treatment strategies and improve visual outcomes.

Authors

Institutions

Publication Details

Journal
Iraqi Journal of Medical and Health Sciences
Published
2025-03-27
DOI
https://doi.org/10.51173/ijmhs.v2i1.27
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual and Structural Differences Between Amblyopic and Non-Amblyopic Eyes in Patients with Unilateral Amblyopia

Masoud Khorrami‐Nejad, Asim Hussein
Iraqi Journal of Medical and Health Sciences
Ophthalmology and Visual Impairment Studies
article

Visual and Structural Differences Between Amblyopic and Non-Amblyopic Eyes in Patients with Unilateral Amblyopia

Masoud Khorrami‐Nejad, Asim Hussein
article en

Abstract

Background: Amblyopia, define as "lazy eye, a neurodevelopmental disorder, manifests as reduced visual acuity not attributable to structural eye abnormalities. Objective of study: This study investigated visual and structural differences between amblyopic and non-amblyopic eyes in children with unilateral amblyopia, focusing on visual acuity, axial length, and lens thickness. Materials and Methods: Twenty-six pediatric patients (5–10 years old) with untreated unilateral functional amblyopia were recruited. Amblyopia was classified as anisometropic, strabismic, or combined. Corrected distance visual acuity (CDVA) was measured in logMAR units. Axial length, anterior chamber depth, and lens thickness were assessed using non-contact optical biometry. Spherical equivalent refractive error was determined via cycloplegic autorefraction. Paired t-tests were used to compare interocular differences. Results: Amblyopic eyes exhibited significantly reduced CDVA. However, no statistically significant interocular differences were found for spherical equivalent, axial length, anterior chamber depth, or lens thickness (all p > 0.05). Amblyopic eyes showed a trend towards shorter axial lengths (mean difference: -0.27 mm, SD: 0.72), particularly in anisometropic amblyopia (-0.21 mm, SD: 0.85). Anterior chamber depth and lens thickness showed minimal interocular variations across amblyopia types. Conclusion: While amblyopic eyes demonstrated reduced visual acuity, interocular differences in biometric parameters were not statistically significant in this small sample. Trends suggest a potential association between amblyopia and shorter axial length, warranting further investigation with larger, longitudinal studies. This research contributes to understanding the ocular and cortical changes in amblyopia, aiming to refine treatment strategies and improve visual outcomes.

Iraqi Journal of Medical and Health SciencesVol. 2(1)
Tehran University of Medical Sciences (IR)
Tehran University of Medical Sciences and Health Services
Openalex Percentile: Top 89%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Visual and Structural Differences Between Amblyopic and Non-Amblyopic Eyes in Patients with Unilateral Amblyopia — Masoud Khorrami‐Nejad, Asim Hussein · Iraqi Journal of Medical and Health Sciences (2025) | TGRS Research Map | TGRS