Accuracy and reliability of anatomical landmarks compared between 3D facial scanning and CBCT radiographs: A comparative study

Introduction: Facial soft tissue evaluation is an important key for the overall patient diagnosis, treatment planning, and long-term prognoses. 3D patient imaging can be an alternative way to define the face providing the clinician with more accurate details, in comparison to the 2D imaging of soft tissues. Objectives: The objective of this study was to evaluate the accuracy and reliability of anatomical landmarks comparing the 3D facial scanning with the CBCT radiographs. Methods: The study was a comparative, crossover and descriptive study. Thirty patients (12 males and 18 females) with 15 to 30 years with a mean age of 22.6 years, who needed orthodontic treatment were recruited from the outpatient clinics, Faculty of Dentistry, Beirut Arab University. All patients had a CBCT radiograph at the beginning with a natural head position and relaxed lips. After that, the patient had 3D facial scanning using the same radiographing machine. Results: The data collected from the 3D facial images and full skull CBCT radiographs were reliable and consistent for most of the measured parameters with Cronbach’s alpha values of 0.870. However, the mouth width parameter exhibited the largest Dahlberg error of 4.08, suggesting substantial variability between the two methods for this parameter. Furthermore, the concordance correlation coefficient (CCC) indicated a positive correlation between the CBCT radiograph and facial scanning for most parameters (average of 0.9). The Bland-Altman revealed a moderate agreement between both sets of scanned measurements with confidence band range (2 and -2), with exceptions, the average mouth width distance (-3.40667). Conclusions: There was a strong positive linear relationship between the two approaches in the majority of the parameters. However, the mouth width parameter revealed a moderately linear relationship between the two approaches.

Authors

Publication Details

Journal
International Arab Journal of Dentistry
Published
2025-04-07
DOI
https://doi.org/10.70174/iajd.v16i1.1392
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy and reliability of anatomical landmarks compared between 3D facial scanning and CBCT radiographs: A comparative study

Nayer Aboelsaad, Aly OSMAN, Mohamad Ahmad Munir SAKHITA
International Arab Journal of Dentistry
Dental Radiography and Imaging
article

Accuracy and reliability of anatomical landmarks compared between 3D facial scanning and CBCT radiographs: A comparative study

Nayer Aboelsaad, Aly OSMAN, Mohamad Ahmad Munir SAKHITA
article en

Abstract

Introduction: Facial soft tissue evaluation is an important key for the overall patient diagnosis, treatment planning, and long-term prognoses. 3D patient imaging can be an alternative way to define the face providing the clinician with more accurate details, in comparison to the 2D imaging of soft tissues. Objectives: The objective of this study was to evaluate the accuracy and reliability of anatomical landmarks comparing the 3D facial scanning with the CBCT radiographs. Methods: The study was a comparative, crossover and descriptive study. Thirty patients (12 males and 18 females) with 15 to 30 years with a mean age of 22.6 years, who needed orthodontic treatment were recruited from the outpatient clinics, Faculty of Dentistry, Beirut Arab University. All patients had a CBCT radiograph at the beginning with a natural head position and relaxed lips. After that, the patient had 3D facial scanning using the same radiographing machine. Results: The data collected from the 3D facial images and full skull CBCT radiographs were reliable and consistent for most of the measured parameters with Cronbach’s alpha values of 0.870. However, the mouth width parameter exhibited the largest Dahlberg error of 4.08, suggesting substantial variability between the two methods for this parameter. Furthermore, the concordance correlation coefficient (CCC) indicated a positive correlation between the CBCT radiograph and facial scanning for most parameters (average of 0.9). The Bland-Altman revealed a moderate agreement between both sets of scanned measurements with confidence band range (2 and -2), with exceptions, the average mouth width distance (-3.40667). Conclusions: There was a strong positive linear relationship between the two approaches in the majority of the parameters. However, the mouth width parameter revealed a moderately linear relationship between the two approaches.

International Arab Journal of DentistryVol. 16(1)
Openalex Percentile: Top 90%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.