Effect of UVA/UVC-activated TiO2 coating on sinks' pipeline system to control biofilm at ICU: A case study from Latvia

Preventing infections caused by antimicrobial-resistant (AMR) pathogens is critical in healthcare settings, particularly in ICUs, where patients are highly susceptible to infections. Sink and pipeline systems display the potential to be the cause of point source outbreaks in intensive care units (ICUs). Here, we performed lab- and real-life experiments to investigate using TiO 2 coating on the inner side of a U-shaped wastewater pipe as the reducer of clinically relevant multidrug-resistant (MDR) microorganisms. During the lab-scale experiments, we evaluated the efficacy of the TiO 2 coating in combination with UVA/UVC light against both Gram(+) and Gram(−) bacterial strains commonly found in ICUs. At the same time, in the pilot experiments that were carried out in a real-life ICU setting, we monitored the changes in the diversity of the microbiological community within a sink that was equipped with the combination of TiO 2 coating and UVA/UVC light source. The lab-scale results showed that TiO 2 coating alone did not have an additional effect on bacteria reduction based on incubation time, power level, and usage time, while the pilot scale demonstrated that TiO 2 coating combination with UVA/UVC light effectively reduced the microbial diversity in the pipeline system of the ICU sink. Overall, this study combines experiments in the laboratory and real-life ICU settings to investigate the effectiveness of a TiO 2 coating and UVA/UVC light combination for eliminating MDR microorganisms, thus providing valuable knowledge that will aid the development of future infection control strategies. Additionally, this study emphasizes the importance of continuous maintenance and monitoring in preventing the growth of MDR bacteria. • The combination of UVA/UVC light and TiO 2 coating reduced growth of MDR strains. • TiO 2 coating helped to avoid MDR formation in the ICU sink and pipeline system. • TiO 2 coating is a valuable solution for infection control in healthcare settings.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-04-01
DOI
https://doi.org/10.1016/j.jwpe.2025.107655
Primary Topic
Infection Control in Healthcare
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of UVA/UVC-activated TiO2 coating on sinks' pipeline system to control biofilm at ICU: A case study from Latvia

Brigita Dejus, Basanti Ekka, Pintó Sala, Mārtiņš Strods et al.
Journal of Water Process Engineering
Infection Control in Healthcare
article

Effect of UVA/UVC-activated TiO2 coating on sinks' pipeline system to control biofilm at ICU: A case study from Latvia

Brigita Dejus, Basanti Ekka, Pintó Sala, Mārtiņš Strods, Tālis Juhna, Dāvids Frīdmanis, Uga Dumpis, Dita Gudrā, Liva Kairisa, Kristens Rascevskis, Inese Jansone
article en

Abstract

Preventing infections caused by antimicrobial-resistant (AMR) pathogens is critical in healthcare settings, particularly in ICUs, where patients are highly susceptible to infections. Sink and pipeline systems display the potential to be the cause of point source outbreaks in intensive care units (ICUs). Here, we performed lab- and real-life experiments to investigate using TiO 2 coating on the inner side of a U-shaped wastewater pipe as the reducer of clinically relevant multidrug-resistant (MDR) microorganisms. During the lab-scale experiments, we evaluated the efficacy of the TiO 2 coating in combination with UVA/UVC light against both Gram(+) and Gram(−) bacterial strains commonly found in ICUs. At the same time, in the pilot experiments that were carried out in a real-life ICU setting, we monitored the changes in the diversity of the microbiological community within a sink that was equipped with the combination of TiO 2 coating and UVA/UVC light source. The lab-scale results showed that TiO 2 coating alone did not have an additional effect on bacteria reduction based on incubation time, power level, and usage time, while the pilot scale demonstrated that TiO 2 coating combination with UVA/UVC light effectively reduced the microbial diversity in the pipeline system of the ICU sink. Overall, this study combines experiments in the laboratory and real-life ICU settings to investigate the effectiveness of a TiO 2 coating and UVA/UVC light combination for eliminating MDR microorganisms, thus providing valuable knowledge that will aid the development of future infection control strategies. Additionally, this study emphasizes the importance of continuous maintenance and monitoring in preventing the growth of MDR bacteria. • The combination of UVA/UVC light and TiO 2 coating reduced growth of MDR strains. • TiO 2 coating helped to avoid MDR formation in the ICU sink and pipeline system. • TiO 2 coating is a valuable solution for infection control in healthcare settings.

Journal of Water Process EngineeringVol. 72
Latvia University of Life Sciences and Technologies (LV), Latvian Biomedical Research and Study Centre (LV), Riga Technical University (LV)
Latvijas Zinātnes Padome
Openalex Percentile: Top 90%
Infection Control in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.