Influence of Web Geometry on Concrete Masonry Walls Subject to Out-of-Plane Loading

An experimental program consisting of 27 partially grouted and reinforced walls was conducted to assess the impact of concrete masonry unit (CMU) web geometry on flexural response when subject to out-of-plane loading given changes to CMU geometry as adopted by ASTM C90 in 2011 that have yet to be vetted in Canada. All walls had the same overall geometry and were constructed with either regular stretcher units conforming to either CSA A165-14 or ASTM C90-23 or knock-out units conforming to ASTM C90-23. The configuration of the longitudinal reinforcement was also varied between wall series such one of that three reinforcing ratios resulted: 0.22, 0.44, or 0.66%. No notable differences in behavior resulted due to differences in the geometry of the concrete masonry units used in wall construction, though the grout columns as included in the reinforced cells appeared to mask the influence of web geometry.

Authors

Institutions

Publication Details

Journal
Canadian Journal of Civil Engineering
Published
2025-03-28
DOI
https://doi.org/10.1139/cjce-2024-0259
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Web Geometry on Concrete Masonry Walls Subject to Out-of-Plane Loading

Lisa R. Feldman, M. Heide
Canadian Journal of Civil Engineering
Masonry and Concrete Structural Analysis
article

Influence of Web Geometry on Concrete Masonry Walls Subject to Out-of-Plane Loading

Lisa R. Feldman, M. Heide
article en

Abstract

An experimental program consisting of 27 partially grouted and reinforced walls was conducted to assess the impact of concrete masonry unit (CMU) web geometry on flexural response when subject to out-of-plane loading given changes to CMU geometry as adopted by ASTM C90 in 2011 that have yet to be vetted in Canada. All walls had the same overall geometry and were constructed with either regular stretcher units conforming to either CSA A165-14 or ASTM C90-23 or knock-out units conforming to ASTM C90-23. The configuration of the longitudinal reinforcement was also varied between wall series such one of that three reinforcing ratios resulted: 0.22, 0.44, or 0.66%. No notable differences in behavior resulted due to differences in the geometry of the concrete masonry units used in wall construction, though the grout columns as included in the reinforced cells appeared to mask the influence of web geometry.

Canadian Journal of Civil Engineering
University of Saskatchewan (CA), Atkinson Noland and Associates (United States) (US)
Openalex Percentile: Top 93%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of Web Geometry on Concrete Masonry Walls Subject to Out-of-Plane Loading — Lisa R. Feldman, M. Heide · Canadian Journal of Civil Engineering (2025) | TGRS Research Map | TGRS