Comparison of the Functional Outcome Between Titanium and Stainless Steel Interlocking Nails in Tibial Shaft Fracture Treatment

The treatment of tibial shaft fractures remains a challenging issue in orthopedic practice. The choice of interlocking nail material, whether titanium or stainless steel, plays a crucial role in functional recovery and complication rates. This study aimed to compare the functional outcomes of treating tibial shaft fractures with titanium versus stainless steel interlocking nails. Methods: A prospective cohort study was conducted with 160 patients who underwent tibial shaft fracture fixation using either titanium (Group A) or stainless steel (Group B) interlocking nails. Functional outcomes were evaluated based on the percentage of excellent, good, fair, and poor outcomes. Additionally, factors such as age, gender, duration of fracture, anatomical side of the fracture, and trauma mechanism were analyzed for their impact on functional outcomes. Statistical significance was set at p < 0.05. Results: The titanium group exhibited superior outcomes, with 72.50% of patients achieving excellent results compared to 58.75% in the stainless steel group. Poor outcomes were significantly lower in the titanium group (5.00%) compared to the stainless steel group (15.00%). Stratification by age, gender, and trauma mechanism revealed that males and patients with fractures treated within 5 days had the best outcomes. Road traffic accidents were linked to poorer recovery outcomes. Conclusion: Titanium interlocking nails resulted in better functional outcomes compared to stainless steel nails in the treatment of tibial shaft fractures. This study suggests that titanium may offer superior performance, with fewer complications and better recovery rates. Further studies are needed to confirm these findings and explore the long-term benefits of titanium nails in fracture healing.

Authors

Institutions

Publication Details

Journal
Biological and Clinical Sciences Research Journal
Published
2025-02-28
DOI
https://doi.org/10.54112/bcsrj.v6i2.1602
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Functional Outcome Between Titanium and Stainless Steel Interlocking Nails in Tibial Shaft Fracture Treatment

Adeed Khan, Ali Miraj Shami
Biological and Clinical Sciences Research Journal
Bone fractures and treatments
article

Comparison of the Functional Outcome Between Titanium and Stainless Steel Interlocking Nails in Tibial Shaft Fracture Treatment

Adeed Khan, Ali Miraj Shami
article en

Abstract

The treatment of tibial shaft fractures remains a challenging issue in orthopedic practice. The choice of interlocking nail material, whether titanium or stainless steel, plays a crucial role in functional recovery and complication rates. This study aimed to compare the functional outcomes of treating tibial shaft fractures with titanium versus stainless steel interlocking nails. Methods: A prospective cohort study was conducted with 160 patients who underwent tibial shaft fracture fixation using either titanium (Group A) or stainless steel (Group B) interlocking nails. Functional outcomes were evaluated based on the percentage of excellent, good, fair, and poor outcomes. Additionally, factors such as age, gender, duration of fracture, anatomical side of the fracture, and trauma mechanism were analyzed for their impact on functional outcomes. Statistical significance was set at p < 0.05. Results: The titanium group exhibited superior outcomes, with 72.50% of patients achieving excellent results compared to 58.75% in the stainless steel group. Poor outcomes were significantly lower in the titanium group (5.00%) compared to the stainless steel group (15.00%). Stratification by age, gender, and trauma mechanism revealed that males and patients with fractures treated within 5 days had the best outcomes. Road traffic accidents were linked to poorer recovery outcomes. Conclusion: Titanium interlocking nails resulted in better functional outcomes compared to stainless steel nails in the treatment of tibial shaft fractures. This study suggests that titanium may offer superior performance, with fewer complications and better recovery rates. Further studies are needed to confirm these findings and explore the long-term benefits of titanium nails in fracture healing.

Biological and Clinical Sciences Research JournalVol. 6(2)
Shaheed Zulfiqar Ali Bhutto Institute of Science and Technology (PK), Pakistan Institute of Medical Sciences (PK)
Openalex Percentile: Top 89%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of the Functional Outcome Between Titanium and Stainless Steel Interlocking Nails in Tibial Shaft Fracture Treatment — Adeed Khan, Ali Miraj Shami · Biological and Clinical Sciences Research Journal (2025) | TGRS Research Map | TGRS