Characterizing the Real-Time Communication Performance of Virtual PLC in Industrial Edge Platform

The integration of virtual Programmable Logic Controllers (vPLCs) into industrial automation systems introduces the potential for enhanced maintainability and scalability through container-based automation. Unlike traditional hardware-based PLCs, vPLCs operate within edge computing environments, leveraging lightweight virtualization to provide flexibility and support modern microservices architectures. However, the open question is: can vPLCs meet the stringent real-time performance requirements of industrial control applications, particularly in communication with sensors and actuators? The paper objective is to fill this gap. Differently from other works in literature, the performance of the real-time data exchange between virtual PLCs and sensors/actuators is evaluated. Inparticular, the paper presents and describes a methodology designed for comparing real PLC and virtual PLC in real-time industrial automation scenarios. The methodology includes the definition of specific performance metrics, the design of a standardized experimental setup to characterize both device real-time performance and uncertainty sources, and the development of analytical models to support simulations and digital twin applications. The proposed method of comparison is demonstrated in a reference use case including real-time Ethernet connectivity; results lead to: a) important conclusions about methodology effectiveness; and b) the analytical model of the considered use case. Indetails, the analysis indicates that vPLCs exhibit approximately 50% higher jitter, suggesting a minimum recommended PROFINET cycle time of 2 ms for optimal performance. The findings contribute to the broader understanding of vPLC capabilities in industrial automation, offering practical insights for industries aiming to transition to modern, containerized control systems without compromising real-time communication performance.

Authors

Institutions

Publication Details

Journal
IEEE Open Journal of Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/ojim.2025.3559573
Citations
4
Primary Topic
Network Time Synchronization Technologies
Type
article
Field-Weighted Citation Impact
5.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterizing the Real-Time Communication Performance of Virtual PLC in Industrial Edge Platform

Stefano Rinaldi, Dennis Brandão, Paolo Ferrari, Emiliano Sisinni et al.
4 citations
IEEE Open Journal of Instrumentation and Measurement
Network Time Synchronization Technologies
5.95
article

Characterizing the Real-Time Communication Performance of Virtual PLC in Industrial Edge Platform

Stefano Rinaldi, Dennis Brandão, Paolo Ferrari, Emiliano Sisinni, Alessandra Flammini, Massimiliano Gaffurini
article en
4 citations

Abstract

The integration of virtual Programmable Logic Controllers (vPLCs) into industrial automation systems introduces the potential for enhanced maintainability and scalability through container-based automation. Unlike traditional hardware-based PLCs, vPLCs operate within edge computing environments, leveraging lightweight virtualization to provide flexibility and support modern microservices architectures. However, the open question is: can vPLCs meet the stringent real-time performance requirements of industrial control applications, particularly in communication with sensors and actuators? The paper objective is to fill this gap. Differently from other works in literature, the performance of the real-time data exchange between virtual PLCs and sensors/actuators is evaluated. Inparticular, the paper presents and describes a methodology designed for comparing real PLC and virtual PLC in real-time industrial automation scenarios. The methodology includes the definition of specific performance metrics, the design of a standardized experimental setup to characterize both device real-time performance and uncertainty sources, and the development of analytical models to support simulations and digital twin applications. The proposed method of comparison is demonstrated in a reference use case including real-time Ethernet connectivity; results lead to: a) important conclusions about methodology effectiveness; and b) the analytical model of the considered use case. Indetails, the analysis indicates that vPLCs exhibit approximately 50% higher jitter, suggesting a minimum recommended PROFINET cycle time of 2 ms for optimal performance. The findings contribute to the broader understanding of vPLC capabilities in industrial automation, offering practical insights for industries aiming to transition to modern, containerized control systems without compromising real-time communication performance.

IEEE Open Journal of Instrumentation and MeasurementVol. 4
University of Brescia (IT)
Openalex Percentile: Top 4%
Network Time Synchronization Technologies
5.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.