Sustainable synthesis of a PtNPs@rGO nanohybrid for detection of toxic fluoride ions using hand-made screen-printed electrodes in aqueous medium
High fluoride (F<sup>-</sup>) concentrations in groundwater affect over 200 million people across 25 countries, making accurate detection and quantification of fluoride in water essential for safety assessment. There is a growing demand for advanced water quality testing systems that provide real-time, location-specific data without requiring specialized expertise. This study presents the development of a simple, eco-friendly, and cost-effective nanosensor for electrochemical F<sup>-</sup> detection in environmental water samples. To our knowledge, this is the first report on the green synthesis of platinum nanoparticles (PtNPs) using <i>Ficus religiosa</i> (sacred fig) leaf extract <i>via</i> a co-precipitation method. Additionally, PtNPs were synthesized <i>ex situ</i> and decorated on reduced graphene oxide (rGO) to form a nanohybrid using ultrasonication. The PtNPs@rGO nanohybrid was then deposited on a disposable screen-printed carbon electrode (SPCE) to fabricate the PtNPs@rGO/SPCE nanosensor using a drop-casting technique. This approach enhances the specificity and sensitivity of the sensor, addressing current analytical challenges. The PtNPs@rGO nanohybrid was characterized by Fourier transform infrared spectroscopy (FTIR), high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), scanning electron microscopy-energy dispersive X-ray (SEM-EDX) analysis, contact angle (CA) measurement, and electrochemical techniques such as differential pulse voltammetry (DPV) and cyclic voltammetry (CV). The PtNPs@rGO/SPCE nanosensor exhibited a wide linear range from 0.001 to 160 μM for F<sup>-</sup> concentrations, with a limit of detection of 10 nM and a limit of quantification of 0.036 μM. The sensitivity was 4.126 μA μM<sup>-1</sup> cm<sup>-2</sup>. The sensor demonstrated excellent reproducibility and strong anti-interference properties. It was successfully applied for F<sup>-</sup> detection in tap, drain, and tube well water samples, yielding satisfactory recoveries, and its performance surpasses those of previously reported sensors for aqueous F<sup>-</sup> sensing.
Authors
- Damini Verma (ORCID: https://orcid.org/0000-0003-1348-6559)
- Kapil Gupta (ORCID: https://orcid.org/0000-0002-9034-6907)
- Pratima R. Solanki (ORCID: https://orcid.org/0000-0003-1679-2180)
- Amit K. Yadav (ORCID: https://orcid.org/0000-0002-2347-3746)
Institutions
- Jawaharlal Nehru University (IN)
- Vinoba Bhave University (IN)
Publication Details
- Journal
- Journal of Materials Chemistry B
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1039/d4tb02115k
- Citations
- 9
- Primary Topic
- Advanced biosensing and bioanalysis techniques
- Type
- article
- Field-Weighted Citation Impact
- 7.25
Funders
- Department of Science and Technology, Ministry of Science and Technology, India