Results of treatment for chronic central serous chorioretinopathy using the IRIDEX IQ577 yellow spectrum diode laser

Objective. To develop a management strategy for patients with chronic serous chorioretinopathy and to assess the effectiveness of focal laser coagulation and subthreshold micropulse laser coagulation in patients with chronic CSC. Material and methods. The study included 13 patients with symptoms of chronic CSC. Optical coherence tomography (OCT) was used to identify the presumed leakage point. Laser coagulation was performed using the IRIDEX IQ577 yellow spectrum diode laser. Results. In cases of focal laser coagulation at the presumed leakage point, a positive effect was observed in 78 % of cases. For subthreshold micropulse laser coagulation in a grid pattern within the area of neuroepithelial detachment, a positive effect was observed in 75 % of cases. Conclusions. Focal laser coagulation and subthreshold micropulse laser coagulation in a grid pattern within the area of neuroepithelial detachment using the IRIDEX IQ577 yellow spectrum diode laser are effective in the treatment of chronic CSC. Keywords: chronic central serous chorioretinopathy, focal retinal laser coagulation, subthreshold micropulse laser coagulation

Authors

Publication Details

Journal
Modern technologies in ophtalmology
Published
2025-03-20
DOI
https://doi.org/10.25276/2312-4911-2025-1-89-94
Primary Topic
Retinal Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Results of treatment for chronic central serous chorioretinopathy using the IRIDEX IQ577 yellow spectrum diode laser

М А Ковалевская, N.K. Polyanskaya, M. A. Kolesnik
Modern technologies in ophtalmology
Retinal Diseases and Treatments
article

Results of treatment for chronic central serous chorioretinopathy using the IRIDEX IQ577 yellow spectrum diode laser

М А Ковалевская, N.K. Polyanskaya, M. A. Kolesnik
article en

Abstract

Objective. To develop a management strategy for patients with chronic serous chorioretinopathy and to assess the effectiveness of focal laser coagulation and subthreshold micropulse laser coagulation in patients with chronic CSC. Material and methods. The study included 13 patients with symptoms of chronic CSC. Optical coherence tomography (OCT) was used to identify the presumed leakage point. Laser coagulation was performed using the IRIDEX IQ577 yellow spectrum diode laser. Results. In cases of focal laser coagulation at the presumed leakage point, a positive effect was observed in 78 % of cases. For subthreshold micropulse laser coagulation in a grid pattern within the area of neuroepithelial detachment, a positive effect was observed in 75 % of cases. Conclusions. Focal laser coagulation and subthreshold micropulse laser coagulation in a grid pattern within the area of neuroepithelial detachment using the IRIDEX IQ577 yellow spectrum diode laser are effective in the treatment of chronic CSC. Keywords: chronic central serous chorioretinopathy, focal retinal laser coagulation, subthreshold micropulse laser coagulation

Modern technologies in ophtalmologyVol. 59(1)
Openalex Percentile: Top 87%
Retinal Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Results of treatment for chronic central serous chorioretinopathy using the IRIDEX IQ577 yellow spectrum diode laser — М А Ковалевская, N.K. Polyanskaya, et al. · Modern technologies in ophtalmology (2025) | TGRS Research Map | TGRS