Comparison of calibration of a rotary piston gas meter G650

Main text The supplementary comparison EURAMET.M.FF-S20 was organized for the purpose of determination of the degree of equivalence of the testing facilities for low-pressure gas flow measurement over the range (50 to 1000) m 3 /h. A rotary displacement gas meter IRM-3-DUO G650 was used as a transfer standard. The measurements were provided at prescribed reference conditions. Participants were nine laboratories from EURAMET: PTB, Germany; CMI, Czech Republic; FORCE TECHNOLOGY, Denmark; VSL, Netherlands; BEV, Austria; GUM, Poland; LEI, Lithuania; RISE, Sweden; METAS, Switzerland. All participants reported their traceability chains to the SI. Relevant results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degrees of equivalence with the KCRV were calculated. All reported results were consistent with the KCRV. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-01-01
DOI
https://doi.org/10.1088/0026-1394/62/1a/07007
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of calibration of a rotary piston gas meter G650

Adam Urbanowicz, Tomáš Valenta, C Berkmann
Metrologia
Flow Measurement and Analysis
article

Comparison of calibration of a rotary piston gas meter G650

Adam Urbanowicz, Tomáš Valenta, C Berkmann
article en

Abstract

Main text The supplementary comparison EURAMET.M.FF-S20 was organized for the purpose of determination of the degree of equivalence of the testing facilities for low-pressure gas flow measurement over the range (50 to 1000) m 3 /h. A rotary displacement gas meter IRM-3-DUO G650 was used as a transfer standard. The measurements were provided at prescribed reference conditions. Participants were nine laboratories from EURAMET: PTB, Germany; CMI, Czech Republic; FORCE TECHNOLOGY, Denmark; VSL, Netherlands; BEV, Austria; GUM, Poland; LEI, Lithuania; RISE, Sweden; METAS, Switzerland. All participants reported their traceability chains to the SI. Relevant results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degrees of equivalence with the KCRV were calculated. All reported results were consistent with the KCRV. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

MetrologiaVol. 62(1A)
Federal Office of Metrology and Surveying (AT), Český metrologický institut (CZ), Central Office of Measures (PL)
Openalex Percentile: Top 92%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.