The impact of monodisperse microbubble size on contrast-enhanced ultrasound super-localization imaging

Contrast-enhanced ultrasound (CEUS) super-localization imaging has shown promise for the assessment of microvascular networks by localizing and tracking microbubbles. The size of the available microbubbles for clinical use is polydisperse, but size-tailorable monodisperse microbubbles are now being developed that present a narrow size distribution. Therefore, proper frequency and pressure tuning have the potential to improve the signal-to-noise ratio and resolution of CEUS acquisitions, which can be expected to increase the performance of CEUS super-localization imaging. In this work, the impact of monodisperse microbubble size on CEUS imaging quality and the efficacy of super-localization imaging was investigated by jointly tuning different frequencies and pressures for different monodisperse microbubble size when performing in vitro CEUS imaging of microbubbles flowing through a dedicated sugar-printed dual-bifurcation microvasculature phantom. The obtained CEUS acquisitions were then post-processed to generate a super-localization output using the Gaussian-centroid localization approach. Four metrics, including generalized contrast-to-noise ratio, full-width half-maximum, number of localization events, and localization F1-score, were employed to quantify the CEUS imaging quality and super-localization performance. In general, jointly optimizing the transmit frequency and pressure for monodisperse microbubbles with smaller size leads to improved CEUS imaging and better super-localization performance. Yet, the weaker backscatter of smaller microbubbles must also be considered.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2025-04-01
DOI
https://doi.org/10.1121/10.0036371
Citations
4
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
2.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of monodisperse microbubble size on contrast-enhanced ultrasound super-localization imaging

Simona Turco, Mike Vargas, Jaap M. J. den Toonder, Hessel Wijkstra et al.
4 citations
The Journal of the Acoustical Society of America
Ultrasound and Hyperthermia Applications
2.70
article

The impact of monodisperse microbubble size on contrast-enhanced ultrasound super-localization imaging

Simona Turco, Mike Vargas, Jaap M. J. den Toonder, Hessel Wijkstra, Andreas Pollet, Massimo Mischi, Lisa Te Winkel, Wim van Hoeve, Peiran Chen
article en
4 citations

Abstract

Contrast-enhanced ultrasound (CEUS) super-localization imaging has shown promise for the assessment of microvascular networks by localizing and tracking microbubbles. The size of the available microbubbles for clinical use is polydisperse, but size-tailorable monodisperse microbubbles are now being developed that present a narrow size distribution. Therefore, proper frequency and pressure tuning have the potential to improve the signal-to-noise ratio and resolution of CEUS acquisitions, which can be expected to increase the performance of CEUS super-localization imaging. In this work, the impact of monodisperse microbubble size on CEUS imaging quality and the efficacy of super-localization imaging was investigated by jointly tuning different frequencies and pressures for different monodisperse microbubble size when performing in vitro CEUS imaging of microbubbles flowing through a dedicated sugar-printed dual-bifurcation microvasculature phantom. The obtained CEUS acquisitions were then post-processed to generate a super-localization output using the Gaussian-centroid localization approach. Four metrics, including generalized contrast-to-noise ratio, full-width half-maximum, number of localization events, and localization F1-score, were employed to quantify the CEUS imaging quality and super-localization performance. In general, jointly optimizing the transmit frequency and pressure for monodisperse microbubbles with smaller size leads to improved CEUS imaging and better super-localization performance. Yet, the weaker backscatter of smaller microbubbles must also be considered.

The Journal of the Acoustical Society of AmericaVol. 157(4)
Eindhoven University of Technology (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Openalex Percentile: Top 11%
Ultrasound and Hyperthermia Applications
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.