An ASIC for ToF-PET application with MCP-PMTs

Abstract The micro-channel plate photomultiplier tube (MCP-PMT) demonstrates excellent sensitivity to single photoelectrons, with a rise time of less than 100 ps. It offers an exceptionally low transit time spread, around 10 ps for multi-photoelectrons and under 50 ps for single photoelectrons. This performance has the potential to enhance coincidence timing, improving image quality in positron emission tomography (PET) and advancing next-generation physics experiments. To meet the stringent demands of picosecond-level time resolution, we developed a prototype frond-end circuit, the FPMROC, designed to accurately measure the time of arrival from the MCP-PMT with a gain of 10 5 . For a target coincidence time resolution of 100 ps, the MCP-PMT contribution is limited to approximately 30 ps, requiring the FPMROC jitter to remain below 10 ps. The FPMROC is implemented using a 55 nm CMOS process and integrates 8 readout channels, a data builder, a high-speed serializer, periphery, and test circuits. Each channel comprises a low-noise preamplifier, discriminator, and time-to-digital converter (TDC) for both time of arrival and time-over-threshold measurements. Digital-to-analog converters, a phase-locked loop, and an serial peripheral interface are used for calibration and threshold adjustment, providing low jitter clocks, and slow control, respectively. Additionally, a charge injection circuit is incorporated for testing and calibration. A prototype design was submitted in July 2024, and the following sections present the architecture, key circuits and simulation results.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-04-01
DOI
https://doi.org/10.1088/1748-0221/20/04/c04024
Citations
1
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An ASIC for ToF-PET application with MCP-PMTs

Chenghui Xia, L. Zhang, Rundong Wan, W. Zhang et al.
1 citations
Journal of Instrumentation
Radiation Effects in Electronics
0.73
article

An ASIC for ToF-PET application with MCP-PMTs

Chenghui Xia, L. Zhang, Rundong Wan, W. Zhang, J. Ye, Bowen Deng, Wenxin Dai, Yinquan Yuan, Xiongbo Yan, Zhifan Zhou, Jie Wang, C. Wang, D. Guo, Lulu Xiao, Gong Zhang, Junyi Huang, Xiaoting Li
article en
1 citations

Abstract

Abstract The micro-channel plate photomultiplier tube (MCP-PMT) demonstrates excellent sensitivity to single photoelectrons, with a rise time of less than 100 ps. It offers an exceptionally low transit time spread, around 10 ps for multi-photoelectrons and under 50 ps for single photoelectrons. This performance has the potential to enhance coincidence timing, improving image quality in positron emission tomography (PET) and advancing next-generation physics experiments. To meet the stringent demands of picosecond-level time resolution, we developed a prototype frond-end circuit, the FPMROC, designed to accurately measure the time of arrival from the MCP-PMT with a gain of 10 5 . For a target coincidence time resolution of 100 ps, the MCP-PMT contribution is limited to approximately 30 ps, requiring the FPMROC jitter to remain below 10 ps. The FPMROC is implemented using a 55 nm CMOS process and integrates 8 readout channels, a data builder, a high-speed serializer, periphery, and test circuits. Each channel comprises a low-noise preamplifier, discriminator, and time-to-digital converter (TDC) for both time of arrival and time-over-threshold measurements. Digital-to-analog converters, a phase-locked loop, and an serial peripheral interface are used for calibration and threshold adjustment, providing low jitter clocks, and slow control, respectively. Additionally, a charge injection circuit is incorporated for testing and calibration. A prototype design was submitted in July 2024, and the following sections present the architecture, key circuits and simulation results.

Journal of InstrumentationVol. 20(04)
Hankou University (CN), Central China Normal University (CN), Wuhan Textile University (CN), Hubei Polytechnic University (CN), Institute of High Energy Physics (AT), Institute of High Energy Physics (CN), State Key Laboratory of Chemical Engineering (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 30%
Radiation Effects in Electronics
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.