The Power Transfer Limit of Converter with Different Reactive Power Control

The paper investigates the impact of diverse control strategies on the power transfer limit (PTL) of converterinterfaced generators (CIGs) grid-connected systems. Specifically, for a converter interfacing with a single infinite bus system, a coupling relationship exists between the system's active power, reactive power, and the voltage at the point of common coupling (PCC). This implies that distinct reactive power control strategies can significantly influence the maximum active power transfer capability of the system. Furthermore, the converter's capacity is typically only slightly greater than its rated power due to its limited overcurrent tolerance. In this paper, the effect of converter capacity constraints on the system ultimate transferred power under different converter control strategies is further considered, and the analytical solution for the converter ultimate transferred power under different control strategy is given. The findings of this research offer theoretical insights that are instrumental for the design of control strategies aimed at integrating CIGs into large-scale power systems via transmission lines.

Authors

Institutions

Publication Details

Published
2024-12-20
DOI
https://doi.org/10.1109/icpee64457.2024.10949952
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Power Transfer Limit of Converter with Different Reactive Power Control

Yinsheng Su, Haicheng Yao, Nailong Wang, Yujun Li et al.
Induction Heating and Inverter Technology
article

The Power Transfer Limit of Converter with Different Reactive Power Control

Yinsheng Su, Haicheng Yao, Nailong Wang, Yujun Li, Guanghu Xu, Bao Li, Qin Gao, Tongpeng Mu
article en

Abstract

The paper investigates the impact of diverse control strategies on the power transfer limit (PTL) of converterinterfaced generators (CIGs) grid-connected systems. Specifically, for a converter interfacing with a single infinite bus system, a coupling relationship exists between the system's active power, reactive power, and the voltage at the point of common coupling (PCC). This implies that distinct reactive power control strategies can significantly influence the maximum active power transfer capability of the system. Furthermore, the converter's capacity is typically only slightly greater than its rated power due to its limited overcurrent tolerance. In this paper, the effect of converter capacity constraints on the system ultimate transferred power under different converter control strategies is further considered, and the analytical solution for the converter ultimate transferred power under different control strategy is given. The findings of this research offer theoretical insights that are instrumental for the design of control strategies aimed at integrating CIGs into large-scale power systems via transmission lines.

China Southern Power Grid (China) (CN), Xi'an Jiaotong University (CN)
China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 71%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.