Theoretical Investigation of Photon Interaction and X-Ray Imaging Performance of PEEK-Based Composites for Medical Implants

Polyetheretherketone (PEEK) is a high-performance, biocompatible polymer with remarkable mechanical properties, making it a promising candidate for medical implants. However, its intrinsic radiolucency poses a challenge for post-operative imaging. This study investigates the photon shielding capabilities and X-ray imaging qualities of pure PEEK and its composites with barium sulfate (BaSO<sub>4</sub>), tantalum (Ta), bismuth oxide (Bi<sub>2</sub>O<sub>3</sub>), and hydroxyapatite (HA). The Monte Carlo-based Geant4 toolkit and the EpiXS application were used to evaluate key photon interaction parameters, including mass attenuation coefficients, effective atomic number (Z<sub>eff</sub>), and effective electron density (N<sub>eff</sub>), as well as the imaging performance metrics such as energy deposition and signal-to-noise ratio (SNR). Results indicate that high atomic number composites significantly enhance PEEK's photon attenuation and imaging contrast. PEEK-Bi<sub>2</sub>O<sub>3</sub> exhibited the highest attenuation coefficients and energy deposition, making it the most effective X-ray shielding material. PEEK-Ta provided a balanced performance with enhanced shielding and lower secondary radiation effects, making it suitable for applications requiring both radiopacity and imaging stability. PEEK-BaSO<sub>4</sub> moderately improved attenuation while maintaining a lower density, offering a trade-off between radiopacity and mechanical properties. Conversely, PEEK-HA demonstrated minimal enhancement in photon attenuation, limiting its effectiveness for radiographic applications. The findings suggest that incorporating high atomic number elements into PEEK significantly enhances its suitability for radiopaque medical implants, allowing for improved post-operative monitoring.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2025-04-07
DOI
https://doi.org/10.3390/polym17070996
Citations
4
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
2.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Theoretical Investigation of Photon Interaction and X-Ray Imaging Performance of PEEK-Based Composites for Medical Implants

Hanan Akhdar
4 citations
Polymers
Radiation Shielding Materials Analysis
2.07
article

Theoretical Investigation of Photon Interaction and X-Ray Imaging Performance of PEEK-Based Composites for Medical Implants

Hanan Akhdar
article en
4 citations

Abstract

Polyetheretherketone (PEEK) is a high-performance, biocompatible polymer with remarkable mechanical properties, making it a promising candidate for medical implants. However, its intrinsic radiolucency poses a challenge for post-operative imaging. This study investigates the photon shielding capabilities and X-ray imaging qualities of pure PEEK and its composites with barium sulfate (BaSO<sub>4</sub>), tantalum (Ta), bismuth oxide (Bi<sub>2</sub>O<sub>3</sub>), and hydroxyapatite (HA). The Monte Carlo-based Geant4 toolkit and the EpiXS application were used to evaluate key photon interaction parameters, including mass attenuation coefficients, effective atomic number (Z<sub>eff</sub>), and effective electron density (N<sub>eff</sub>), as well as the imaging performance metrics such as energy deposition and signal-to-noise ratio (SNR). Results indicate that high atomic number composites significantly enhance PEEK's photon attenuation and imaging contrast. PEEK-Bi<sub>2</sub>O<sub>3</sub> exhibited the highest attenuation coefficients and energy deposition, making it the most effective X-ray shielding material. PEEK-Ta provided a balanced performance with enhanced shielding and lower secondary radiation effects, making it suitable for applications requiring both radiopacity and imaging stability. PEEK-BaSO<sub>4</sub> moderately improved attenuation while maintaining a lower density, offering a trade-off between radiopacity and mechanical properties. Conversely, PEEK-HA demonstrated minimal enhancement in photon attenuation, limiting its effectiveness for radiographic applications. The findings suggest that incorporating high atomic number elements into PEEK significantly enhances its suitability for radiopaque medical implants, allowing for improved post-operative monitoring.

PolymersVol. 17(7)
Imam Mohammad ibn Saud Islamic University (SA)
Imam Mohammed Ibn Saud Islamic University, Al-Imam Muhammad Ibn Saud Islamic University
Openalex Percentile: Top 14%
Radiation Shielding Materials Analysis
2.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Theoretical Investigation of Photon Interaction and X-Ray Imaging Performance of PEEK-Based Composites for Medical Implants — Hanan Akhdar · Polymers (2025) | TGRS Research Map | TGRS