Fault Analysis of Transformer Winding Based on Frequency Response Method

It is difficult to obtain the fault frequency response curve in the transformers actually running in the field, and the cost of large transformers is expensive. Most of the fault simulation is destructive test, and the simulation of winding fault needs to pay a high price. Therefore, in this paper, a fault simulation test platform for autotransformer winding is built for the series winding structure. A large number of axial shift, short circuit and parallel capacitor faults are simulated, and corresponding amplitude-frequency characteristic curves and phase-frequency characteristic curves are obtained, which can provide data basis for transformer winding fault diagnosis.

Authors

Institutions

Publication Details

Published
2024-12-20
DOI
https://doi.org/10.1109/icpee64457.2024.10950003
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Analysis of Transformer Winding Based on Frequency Response Method

Zhangquan Rao, Zhou Dan, Shuo Jiang, Lijun Zhou et al.
Power Transformer Diagnostics and Insulation
article

Fault Analysis of Transformer Winding Based on Frequency Response Method

Zhangquan Rao, Zhou Dan, Shuo Jiang, Lijun Zhou, Yao Cong-Wei, Pang Xiao‐feng, Linglong Cai, Min Xiyao
article en

Abstract

It is difficult to obtain the fault frequency response curve in the transformers actually running in the field, and the cost of large transformers is expensive. Most of the fault simulation is destructive test, and the simulation of winding fault needs to pay a high price. Therefore, in this paper, a fault simulation test platform for autotransformer winding is built for the series winding structure. A large number of axial shift, short circuit and parallel capacitor faults are simulated, and corresponding amplitude-frequency characteristic curves and phase-frequency characteristic curves are obtained, which can provide data basis for transformer winding fault diagnosis.

Southwest Jiaotong University (CN), China Southern Power Grid (China) (CN)
China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 73%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.