A wide-range Raman shift wavenumber measure based on a polymer material.

The wave number of the Raman shift is one of the most important parameters in Raman spectroscopy. Since the accuracy of determining the wave number of the Raman shift strongly depends on the technical characteristics of the Raman spectrometers and the measurement conditions, physically and chemically stable reference materials that would be convenient for users are required to calibrate such devices on the wave number scale. One of the promising areas of development of such reference materials that meet these requirements are solid-state reference materials developed in our country and abroad. A Raman shift wave number measure has been developed and tested for the purpose of approving the type of measuring instrument. The measure is intended for calibration and verification of measuring instruments on the scale of Raman shift wave numbers. The measure is a polymer film consisting of polystyrene and sulfur and placed in a special mandrel. The measure material is in a solid aggregate state. The metrological characteristics of the developed measure have been studied. It has been established that the measure allows storing and transmitting a unit of Raman shift wave numbers for Raman scattering excitation wavelengths of 532–785 nm in the range of 80–3000 cm –1 with an error of no more than 1 cm –1 . Traceability is ensured to the State primary special standard of units of energy, energy density distribution, pulse duration and wavelength of laser radiation GET 187-2016 and the State working standard of the unit of wavelength for fiber-optic information transmission systems in the range of values from 0.4 to 3.4 μm (3.1.ZZA.0114.2018). The combination of polystyrene and sulfur lines in the Raman spectrum of the developed measure made it possible to expand (in comparison with the range of similar solid-state measures of foreign production) the range of wave numbers of Raman shifts, especially in the short-wave region.

Authors

Institutions

Publication Details

Journal
Izmeritel`naya Tekhnika
Published
2025-04-03
DOI
https://doi.org/10.32446/0368-1025it.2025-1-77-82
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A wide-range Raman shift wavenumber measure based on a polymer material.

M. K. Alenichev, A. A. Yushina
Izmeritel`naya Tekhnika
Spectroscopy Techniques in Biomedical and Chemical Research
article

A wide-range Raman shift wavenumber measure based on a polymer material.

M. K. Alenichev, A. A. Yushina
article en

Abstract

The wave number of the Raman shift is one of the most important parameters in Raman spectroscopy. Since the accuracy of determining the wave number of the Raman shift strongly depends on the technical characteristics of the Raman spectrometers and the measurement conditions, physically and chemically stable reference materials that would be convenient for users are required to calibrate such devices on the wave number scale. One of the promising areas of development of such reference materials that meet these requirements are solid-state reference materials developed in our country and abroad. A Raman shift wave number measure has been developed and tested for the purpose of approving the type of measuring instrument. The measure is intended for calibration and verification of measuring instruments on the scale of Raman shift wave numbers. The measure is a polymer film consisting of polystyrene and sulfur and placed in a special mandrel. The measure material is in a solid aggregate state. The metrological characteristics of the developed measure have been studied. It has been established that the measure allows storing and transmitting a unit of Raman shift wave numbers for Raman scattering excitation wavelengths of 532–785 nm in the range of 80–3000 cm –1 with an error of no more than 1 cm –1 . Traceability is ensured to the State primary special standard of units of energy, energy density distribution, pulse duration and wavelength of laser radiation GET 187-2016 and the State working standard of the unit of wavelength for fiber-optic information transmission systems in the range of values from 0.4 to 3.4 μm (3.1.ZZA.0114.2018). The combination of polystyrene and sulfur lines in the Raman spectrum of the developed measure made it possible to expand (in comparison with the range of similar solid-state measures of foreign production) the range of wave numbers of Raman shifts, especially in the short-wave region.

Izmeritel`naya TekhnikaVol. 74(1)
All-Russian Research Institute for Optical and Physical Measurements (RU)
Openalex Percentile: Top 94%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A wide-range Raman shift wavenumber measure based on a polymer material. — M. K. Alenichev, A. A. Yushina · Izmeritel`naya Tekhnika (2025) | TGRS Research Map | TGRS