Control of the superconducting magnet positioned on the DN-12 diffractometer of the IBR-2 reactor

Abstract A Helmholtz coil-like superconducting magnet using a material with high-temperature superconductivity (HTSC) has been produced for the DN-12 diffractometer of the IBR-2 reactor in the Department of the Spectrometers Complex of FLNP. The magnet cryostat possesses a horizontal shaft for loading the high-pressure chamber that is introduced into the area of high magnetic field. The temperature of the high-pressure chamber can be varied using an electric heater in the range of (3.6 - 150) K and the chamber is cooled using a closed cycle cryocooler as part of the cryostat insert that is introduced into the shaft together with the high-pressure chamber. The temperature of the magnet windings ranges from 20 to 40 K and is maintained using a closed cycle cryocooler. The equipment bound in the system that controls the magnet, magnet current supply, temperature controllers, cryostat vacuum measurements, the pumping system control – vacuum maintenance and compressor control of both cryocoolers are discussed in the report. The logical scheme of this system operation is considered as well. The equipment of the superconducting magnet environment provides such magnet parameters as magnetic induction, temperature of HTS coils and current leads in the cryostat. The core of the system is the current source and two cryocoolers. The sequence of switching on all units of the environment is implemented in such a way as to prevent the magnet equipment from operating outside the safe temperature range and to prevent its inadvertent transition to the regular state, in this case, emergency current removal from the HTS coil is provided.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-04-01
DOI
https://doi.org/10.1088/1742-6596/2984/1/012004
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Control of the superconducting magnet positioned on the DN-12 diffractometer of the IBR-2 reactor

A. V. Rutkauskas, A. V. Altynov, A. N. Chernikov
Journal of Physics Conference Series
Nuclear Physics and Applications
article

Control of the superconducting magnet positioned on the DN-12 diffractometer of the IBR-2 reactor

A. V. Rutkauskas, A. V. Altynov, A. N. Chernikov
article en

Abstract

Abstract A Helmholtz coil-like superconducting magnet using a material with high-temperature superconductivity (HTSC) has been produced for the DN-12 diffractometer of the IBR-2 reactor in the Department of the Spectrometers Complex of FLNP. The magnet cryostat possesses a horizontal shaft for loading the high-pressure chamber that is introduced into the area of high magnetic field. The temperature of the high-pressure chamber can be varied using an electric heater in the range of (3.6 - 150) K and the chamber is cooled using a closed cycle cryocooler as part of the cryostat insert that is introduced into the shaft together with the high-pressure chamber. The temperature of the magnet windings ranges from 20 to 40 K and is maintained using a closed cycle cryocooler. The equipment bound in the system that controls the magnet, magnet current supply, temperature controllers, cryostat vacuum measurements, the pumping system control – vacuum maintenance and compressor control of both cryocoolers are discussed in the report. The logical scheme of this system operation is considered as well. The equipment of the superconducting magnet environment provides such magnet parameters as magnetic induction, temperature of HTS coils and current leads in the cryostat. The core of the system is the current source and two cryocoolers. The sequence of switching on all units of the environment is implemented in such a way as to prevent the magnet equipment from operating outside the safe temperature range and to prevent its inadvertent transition to the regular state, in this case, emergency current removal from the HTS coil is provided.

Journal of Physics Conference SeriesVol. 2984(1)
Joint Institute for Nuclear Research (RU)
Openalex Percentile: Top 91%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Control of the superconducting magnet positioned on the DN-12 diffractometer of the IBR-2 reactor — A. V. Rutkauskas, A. V. Altynov, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS