Study on Dopamine Electrochemical Sensing Basedon Au@MoS<sub>2</sub>

Dopamine (DA) is a vital neurotransmitter, and accurate detection of its concentration is critical for both clinical diagnostics and neuroscience research. Due to its electrochemical activity, DA is commonly detected using electrochemical methods, which are favored for their simplicity, fast response time, and suitability for in vivo analysis. In this work, a highly sensitive DA electrochemical sensor was developed using an Au@MoS2 composite, created by modifying molybdenum disulfide (MoS2) nanosheets with gold nanoparticles through HAuCl4 reduction, and it was aimed at enhancing DA adsorption and improving detection performance. Scanning Electron Microscopy (SEM), transmission electron microscopy (TEM), Energy Dispersive Spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS) and X-ray Diffraction (XRD) confirmed the successful synthesis of Au@MoS2 and the uniform distribution of gold nanoparticles across the MoS2 nanosheets. Then, the electrochemical characterization demonstrated that the Au@MoS2/GCE exhibited distinct oxidation peaks in a 10 μmol·L–1 DA solution, with significantly enhanced electrochemical activity compared to both unmodified GCE and pristine MoS2. Furthermore, differential pulse voltammetry (DPV) further revealed a strong linear relationship between DA concentration and the current response in the range of 800 nmol·L–1 to 10 μmol·L–1, with a low detection limit (LOD) of 78.9 nmol·L–1 (S/N = 3). Additionally, the sensor showed excellent selectivity against other interfering substances. Moreover, the laser-induced Au@MoS2 (LIAu@MoS2), with its abundance of negatively charged surface defects, enabled the ultra-sensitive detection of the ultra-low concentrations of DA. In conclusion, the successfully fabricated Au@MoS2 based sensor offers advantages such as low cost, ease of operation, and scalability, making it a promising candidate for biosensing applications due to its enhanced DA detection capabilities.

Publication Details

Journal
Journal of Electrochemistry
Published
2025-03-28
DOI
https://doi.org/10.61558/2993-074x.3536
Citations
2
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Dopamine Electrochemical Sensing Basedon Au@MoS2

2 citations
Journal of Electrochemistry
Conducting polymers and applications
1.21
article

Study on Dopamine Electrochemical Sensing Basedon Au@MoS2

article en
2 citations

Abstract

Dopamine (DA) is a vital neurotransmitter, and accurate detection of its concentration is critical for both clinical diagnostics and neuroscience research. Due to its electrochemical activity, DA is commonly detected using electrochemical methods, which are favored for their simplicity, fast response time, and suitability for in vivo analysis. In this work, a highly sensitive DA electrochemical sensor was developed using an Au@MoS2 composite, created by modifying molybdenum disulfide (MoS2) nanosheets with gold nanoparticles through HAuCl4 reduction, and it was aimed at enhancing DA adsorption and improving detection performance. Scanning Electron Microscopy (SEM), transmission electron microscopy (TEM), Energy Dispersive Spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS) and X-ray Diffraction (XRD) confirmed the successful synthesis of Au@MoS2 and the uniform distribution of gold nanoparticles across the MoS2 nanosheets. Then, the electrochemical characterization demonstrated that the Au@MoS2/GCE exhibited distinct oxidation peaks in a 10 μmol·L–1 DA solution, with significantly enhanced electrochemical activity compared to both unmodified GCE and pristine MoS2. Furthermore, differential pulse voltammetry (DPV) further revealed a strong linear relationship between DA concentration and the current response in the range of 800 nmol·L–1 to 10 μmol·L–1, with a low detection limit (LOD) of 78.9 nmol·L–1 (S/N = 3). Additionally, the sensor showed excellent selectivity against other interfering substances. Moreover, the laser-induced Au@MoS2 (LIAu@MoS2), with its abundance of negatively charged surface defects, enabled the ultra-sensitive detection of the ultra-low concentrations of DA. In conclusion, the successfully fabricated Au@MoS2 based sensor offers advantages such as low cost, ease of operation, and scalability, making it a promising candidate for biosensing applications due to its enhanced DA detection capabilities.

Journal of ElectrochemistryVol. 31(3)
National Natural Science Foundation of China, Zhengzhou University, State Tobacco Monopoly Administration
Openalex Percentile: Top 24%
Conducting polymers and applications
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.