A calcified, eroded, and thrombosed Mustard: recurrent embolic strokes in a patient with dextro-transpostion of the great arteries corrected by atrial switch—case report

A case of recurrent cardioembolic strokes long after Mustard surgery due to thrombi on a heavily calcified pericardial patch is presented. A fracture in the patch led to the exposure of thrombogenic material, which had accumulated around the pacemaker (PM) leads on the systemic venous side of the baffle. This exposure allowed thrombotic material to reach the pulmonary venous side, ultimately entering the subaortic right ventricle and the systemic circulation. In the Mustard procedure, the material used for the baffle construction is prone to degeneration and calcification over time. We hypothesize that chronic mechanical stress from the PM leads might have contributed to the gradual erosion and fracture and consequently thrombosis of the heavily calcified patch, leading to recurrent strokes. Surgery became necessary as aggressive anticoagulation failed to prevent thrombus recurrence.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Case Reports
Published
2025-03-27
DOI
https://doi.org/10.1093/ehjcr/ytaf150
Citations
2
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
2.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A calcified, eroded, and thrombosed Mustard: recurrent embolic strokes in a patient with dextro-transpostion of the great arteries corrected by atrial switch—case report

Antonio González‐Calle, Pastora Gallego, Miguel Á. Japón, Francisco Javier Ruperti‐Repilado et al.
2 citations
European Heart Journal - Case Reports
Acute Ischemic Stroke Management
2.71
article

A calcified, eroded, and thrombosed Mustard: recurrent embolic strokes in a patient with dextro-transpostion of the great arteries corrected by atrial switch—case report

Antonio González‐Calle, Pastora Gallego, Miguel Á. Japón, Francisco Javier Ruperti‐Repilado, Amadeo Wals Rodríguez
article en
2 citations

Abstract

A case of recurrent cardioembolic strokes long after Mustard surgery due to thrombi on a heavily calcified pericardial patch is presented. A fracture in the patch led to the exposure of thrombogenic material, which had accumulated around the pacemaker (PM) leads on the systemic venous side of the baffle. This exposure allowed thrombotic material to reach the pulmonary venous side, ultimately entering the subaortic right ventricle and the systemic circulation. In the Mustard procedure, the material used for the baffle construction is prone to degeneration and calcification over time. We hypothesize that chronic mechanical stress from the PM leads might have contributed to the gradual erosion and fracture and consequently thrombosis of the heavily calcified patch, leading to recurrent strokes. Surgery became necessary as aggressive anticoagulation failed to prevent thrombus recurrence.

European Heart Journal - Case ReportsVol. 9(4)
University Hospital of Basel (CH), Hospital Base (CL), Instituto de Biomedicina de Sevilla (ES), ERN GUARD-Heart (NL), Hospital Universitario Virgen del Rocío (ES)
National Science Foundation, Universität Basel, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Openalex Percentile: Top 11%
Acute Ischemic Stroke Management
2.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.