Comparison of Hydrophilic Properties of Titanium and Zirconia Dental Implants’ Surfaces

One of the key factors influencing osseointegration is the hydrophilicity of the surface of dental implants; high hydrophilicity is more advantageous than low hydrophilicity. This study aimed to compare the hydrophilic properties of titanium and zirconia implants from different manufacturers. An in vitro analysis was conducted on 15 implants-13 titanium and 2 zirconia-each featuring distinct compositions and surface treatments. Their hydrophilicity was assessed using the contact angle method, where a drop of saline solution was pipetted onto the apical part of the implant. For each implant, 30 contact angle measurements were taken at three different surface wetting time intervals. The contact angle is defined as the internal angle between the tangent to the surface of the liquid and the surface at the point of tangency; a smaller angle means a higher hydrophilicity. The results show that titanium implants from BTI UniCa, Nobel TiUltra, and Straumann Roxolid SLActive-which are classified as premium implants-exhibited the highest hydrophilicity. In contrast, zirconia implants demonstrated significantly lower hydrophilicity. Within this group, the Nobel Pearl implant exhibited smaller contact angles than the Bredent WhiteSKY implant. Our findings confirm that high-quality titanium implants show superior hydrophilicity, potentially improving clinical outcomes by accelerating healing and facilitating immediate loading protocols, but this could only be proven with an in vivo animal study. Conversely, the relatively lower hydrophilicity of zirconia implants highlights the need for continued advancements in zirconia composition and surface modification to optimize their osseointegration potential.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-04-09
DOI
https://doi.org/10.3390/ma18081724
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Hydrophilic Properties of Titanium and Zirconia Dental Implants’ Surfaces

Luka Morelato, Valentina Petrović, Vlatko Kopić, Dragana Gabrić et al.
Materials
Dental materials and restorations
article

Comparison of Hydrophilic Properties of Titanium and Zirconia Dental Implants’ Surfaces

Luka Morelato, Valentina Petrović, Vlatko Kopić, Dragana Gabrić, Ticijana Ban, Marko Vuletić, Tadej Čivljak
article en

Abstract

One of the key factors influencing osseointegration is the hydrophilicity of the surface of dental implants; high hydrophilicity is more advantageous than low hydrophilicity. This study aimed to compare the hydrophilic properties of titanium and zirconia implants from different manufacturers. An in vitro analysis was conducted on 15 implants-13 titanium and 2 zirconia-each featuring distinct compositions and surface treatments. Their hydrophilicity was assessed using the contact angle method, where a drop of saline solution was pipetted onto the apical part of the implant. For each implant, 30 contact angle measurements were taken at three different surface wetting time intervals. The contact angle is defined as the internal angle between the tangent to the surface of the liquid and the surface at the point of tangency; a smaller angle means a higher hydrophilicity. The results show that titanium implants from BTI UniCa, Nobel TiUltra, and Straumann Roxolid SLActive-which are classified as premium implants-exhibited the highest hydrophilicity. In contrast, zirconia implants demonstrated significantly lower hydrophilicity. Within this group, the Nobel Pearl implant exhibited smaller contact angles than the Bredent WhiteSKY implant. Our findings confirm that high-quality titanium implants show superior hydrophilicity, potentially improving clinical outcomes by accelerating healing and facilitating immediate loading protocols, but this could only be proven with an in vivo animal study. Conversely, the relatively lower hydrophilicity of zirconia implants highlights the need for continued advancements in zirconia composition and surface modification to optimize their osseointegration potential.

MaterialsVol. 18(8)
University Hospital Centre Zagreb (HR), University of Zagreb (HR), Institute of Physics (HR), University of Osijek (HR)
Openalex Percentile: Top 92%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.