Body composition assessment with different bioimpedance devices. Which one is a better choice?

Nowadays, due to their widespread application, various models of bioelectrical impedance analysis (BIA) devices have become available. However, differences in multiple parameters among these BIA devices pose a significant challenge despite their common underlying principle. The primary aim of this research was to assess the correlation, agreement, and differences in specific body composition parameters-body fat percentage (BF%) and muscle mass percentage (Muscle%)-measured by three distinct BIA devices (Omron BF300, Omron BF511, and InBody 770). Measurements were conducted by the same examiner, on the same day, in a sample of 35 women aged between 21 and 26 years. Participants’ baseline characteristics (age, body height, body mass, body mass index) were recorded, alongside their body composition values (BF% and Muscle%) obtained using the three, i.e. two BIA devices, respectively. Data analysis employed SPSS 26.0 software, applying descriptive statistics, Pearson’s correlation coefficient, concordance coefficient, repeated measures ANOVA, paired sample t-test, and Bland-Altman plots. Results demonstrated statistically significant correlations (p=0.000) for BF% across all three BIA devices, and for Muscle% between Omron BF511 and InBody 770. Additionally, a significant correlation (p=0.000) with high concordance was noted (W=0.939 for BF%, W=0.926 for Muscle%), although significant differences among devices were also evident (p<0.001). Given the absence of a universally accepted reference method and considering the prior validation of InBody devices against DXA, the InBody 770 is recommended for accuracy when possible. However, for field assessments requiring portable solutions, the Omron BF511 is preferred due to its practicality in terms of size, weight, and portability.

Authors

Publication Details

Journal
Interciencia
Published
2025-01-01
DOI
https://doi.org/10.59671/ceipi
Citations
1
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Body composition assessment with different bioimpedance devices. Which one is a better choice?

Stefan Stojanović, İsmail Ilbak, Tijana Purenovic Ivanovic, Katarzyna Sterkowicz Przybycien
1 citations
Interciencia
Body Composition Measurement Techniques
1.16
article

Body composition assessment with different bioimpedance devices. Which one is a better choice?

Stefan Stojanović, İsmail Ilbak, Tijana Purenovic Ivanovic, Katarzyna Sterkowicz Przybycien
article en
1 citations

Abstract

Nowadays, due to their widespread application, various models of bioelectrical impedance analysis (BIA) devices have become available. However, differences in multiple parameters among these BIA devices pose a significant challenge despite their common underlying principle. The primary aim of this research was to assess the correlation, agreement, and differences in specific body composition parameters-body fat percentage (BF%) and muscle mass percentage (Muscle%)-measured by three distinct BIA devices (Omron BF300, Omron BF511, and InBody 770). Measurements were conducted by the same examiner, on the same day, in a sample of 35 women aged between 21 and 26 years. Participants’ baseline characteristics (age, body height, body mass, body mass index) were recorded, alongside their body composition values (BF% and Muscle%) obtained using the three, i.e. two BIA devices, respectively. Data analysis employed SPSS 26.0 software, applying descriptive statistics, Pearson’s correlation coefficient, concordance coefficient, repeated measures ANOVA, paired sample t-test, and Bland-Altman plots. Results demonstrated statistically significant correlations (p=0.000) for BF% across all three BIA devices, and for Muscle% between Omron BF511 and InBody 770. Additionally, a significant correlation (p=0.000) with high concordance was noted (W=0.939 for BF%, W=0.926 for Muscle%), although significant differences among devices were also evident (p<0.001). Given the absence of a universally accepted reference method and considering the prior validation of InBody devices against DXA, the InBody 770 is recommended for accuracy when possible. However, for field assessments requiring portable solutions, the Omron BF511 is preferred due to its practicality in terms of size, weight, and portability.

Interciencia
Openalex Percentile: Top 24%
Body Composition Measurement Techniques
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.