Punching shear behavior of full-scaled reinforced concrete slab-column connection after cooling from fire-induced elevated temperature

Elevated temperatures caused by fire will deteriorate the behavior of reinforced concrete (RC) structures significantly. In addition, after cooling from elevated temperatures, RC structures will exhibit a significant reduction in load-bearing capacity due to material degradation and internal damage. Understanding the residual behavior of RC structure after fire is crucial for determining whether dismantling and repair strategies. However, limited studies have paid concern on the residual behavior of RC flat slabs after exposure to fire and subsequent cooling. To fill this research gap, a series of full-scale RC slab-column connections were fabricated and tested. The objective of the study was to assess the residual punching shear behavior of RC slab-column connections after cooling from elevated temperatures. The specimens were categorized into two groups based on the flexural reinforcement ratio of the slab: 0.55 % and 0.94 %. The test results show that, after cooling from elevated temperatures, RC slab-column connections with low reinforcement ratio experienced a shift in failure mode from flexural-punching failure to pure punching shear failure, which is quite dangerous in practice design. Furthermore, to improve the prediction of the residual punching shear capacity of RC slab-column connections after cooling from fire exposure, the Critical Shear Crack Theory (CSCT) model was modified by considering the deterioration of the material properties, reducing of the effective slab thickness and widening of the critical shear crack due to high temperature. By comparison of the analytical results with the test one, the proposed model demonstrated high accuracy with less discreteness. • Punching shear capacity of full-scale RC slab-column connection after cooling from elevated temperature was investigated. • Effects of elevated temperature on punching shear resistance of the connection were quantified. • Failure modes of the connections after cooling from elevated temperature were analyzed. • Analytical model to predict punching shear capacity and failure mode of the connection was proposed.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-04-09
DOI
https://doi.org/10.1016/j.engstruct.2025.120216
Citations
18
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
17.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Punching shear behavior of full-scaled reinforced concrete slab-column connection after cooling from fire-induced elevated temperature

Kai Qian, Yun-Hao Weng, Zhijun Hu
18 citations
Engineering Structures
Fire effects on concrete materials
17.16
article

Punching shear behavior of full-scaled reinforced concrete slab-column connection after cooling from fire-induced elevated temperature

Kai Qian, Yun-Hao Weng, Zhijun Hu
article en
18 citations

Abstract

Elevated temperatures caused by fire will deteriorate the behavior of reinforced concrete (RC) structures significantly. In addition, after cooling from elevated temperatures, RC structures will exhibit a significant reduction in load-bearing capacity due to material degradation and internal damage. Understanding the residual behavior of RC structure after fire is crucial for determining whether dismantling and repair strategies. However, limited studies have paid concern on the residual behavior of RC flat slabs after exposure to fire and subsequent cooling. To fill this research gap, a series of full-scale RC slab-column connections were fabricated and tested. The objective of the study was to assess the residual punching shear behavior of RC slab-column connections after cooling from elevated temperatures. The specimens were categorized into two groups based on the flexural reinforcement ratio of the slab: 0.55 % and 0.94 %. The test results show that, after cooling from elevated temperatures, RC slab-column connections with low reinforcement ratio experienced a shift in failure mode from flexural-punching failure to pure punching shear failure, which is quite dangerous in practice design. Furthermore, to improve the prediction of the residual punching shear capacity of RC slab-column connections after cooling from fire exposure, the Critical Shear Crack Theory (CSCT) model was modified by considering the deterioration of the material properties, reducing of the effective slab thickness and widening of the critical shear crack due to high temperature. By comparison of the analytical results with the test one, the proposed model demonstrated high accuracy with less discreteness. • Punching shear capacity of full-scale RC slab-column connection after cooling from elevated temperature was investigated. • Effects of elevated temperature on punching shear resistance of the connection were quantified. • Failure modes of the connections after cooling from elevated temperature were analyzed. • Analytical model to predict punching shear capacity and failure mode of the connection was proposed.

Engineering StructuresVol. 334
Guilin University of Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Guangxi Province
Sustainable cities and communities
Openalex Percentile: Top 1%
Fire effects on concrete materials
17.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.