Slenderness effect on GFRP-RC columns with square spirals under concentric and eccentric loading: Experimental and analytical study

This study investigates the behavior of slender glass fiber-reinforced polymer-reinforced concrete (GFRP-RC) columns, specifically those reinforced with GFRP bars and square spirals. Nine column specimens were tested, with varying slenderness ratios of 20, 40, and 60, and load eccentricities of 0 %, 15 %, and 30 % of the section height. Under concentric loading, increased slenderness led to a 16–31 % decrease in column strength, primarily due to amplified bending moments and lateral deformations, worsened by the asymmetry of the square spirals. Under eccentric loading, spiral rupture was observed only at a slenderness ratio of 20 and 15 % eccentricity. Spirals provided critical stability for shorter columns under moderate loads, but their effectiveness diminished in more slender columns and under higher eccentricities. As slenderness increased, the spirals’ contribution to confinement and load-bearing capacity decreased; for instance, at 15 % eccentricity, increasing slenderness from 20 to 60 reduced load capacity by 13 % and 32 %, respectively. A transition in failure mode from compression-dominated to bending-dominated failure was observed as eccentricity increased. An analytical model, assuming sine-shaped deformation for single-curvature bending, was developed and validated against experimental data. Based on this, a slenderness limit of 14 for GFRP-RC columns with 2–4 % longitudinal reinforcement ratio was recommended. • Slender GFRP-RC columns with square spirals were tested, and an analytical model was developed and validated. • Tests included concentric and eccentric loading (15%, 30%) with slenderness ratios of 20, 40, and 60. • A slenderness limit of 14 is recommended for GFRP-RC columns with longitudinal reinforcement ratios ranging from 2 % to 4 %.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-04-09
DOI
https://doi.org/10.1016/j.engstruct.2025.120277
Citations
4
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
4.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Slenderness effect on GFRP-RC columns with square spirals under concentric and eccentric loading: Experimental and analytical study

Alireza Sadat Hosseini, Pedram Sadeghian
4 citations
Engineering Structures
Structural Behavior of Reinforced Concrete
4.03
article

Slenderness effect on GFRP-RC columns with square spirals under concentric and eccentric loading: Experimental and analytical study

Alireza Sadat Hosseini, Pedram Sadeghian
article en
4 citations

Abstract

This study investigates the behavior of slender glass fiber-reinforced polymer-reinforced concrete (GFRP-RC) columns, specifically those reinforced with GFRP bars and square spirals. Nine column specimens were tested, with varying slenderness ratios of 20, 40, and 60, and load eccentricities of 0 %, 15 %, and 30 % of the section height. Under concentric loading, increased slenderness led to a 16–31 % decrease in column strength, primarily due to amplified bending moments and lateral deformations, worsened by the asymmetry of the square spirals. Under eccentric loading, spiral rupture was observed only at a slenderness ratio of 20 and 15 % eccentricity. Spirals provided critical stability for shorter columns under moderate loads, but their effectiveness diminished in more slender columns and under higher eccentricities. As slenderness increased, the spirals’ contribution to confinement and load-bearing capacity decreased; for instance, at 15 % eccentricity, increasing slenderness from 20 to 60 reduced load capacity by 13 % and 32 %, respectively. A transition in failure mode from compression-dominated to bending-dominated failure was observed as eccentricity increased. An analytical model, assuming sine-shaped deformation for single-curvature bending, was developed and validated against experimental data. Based on this, a slenderness limit of 14 for GFRP-RC columns with 2–4 % longitudinal reinforcement ratio was recommended. • Slender GFRP-RC columns with square spirals were tested, and an analytical model was developed and validated. • Tests included concentric and eccentric loading (15%, 30%) with slenderness ratios of 20, 40, and 60. • A slenderness limit of 14 is recommended for GFRP-RC columns with longitudinal reinforcement ratios ranging from 2 % to 4 %.

Engineering StructuresVol. 334
Dalhousie University (CA)
Pultrall, Dalhousie University, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 7%
Structural Behavior of Reinforced Concrete
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.