Submillimeter Pixelated SPECT Detector Using GAGG:Ce and Light Guide With Optical Barrier Slits

In nuclear medicine imaging systems, intrinsic spatial resolution of the detector is one of the most important performance metrics. In this work, we aim to develop a high-resolution single photon emission computed tomography (SPECT) detector using pixelated Cedoped gadolinium aluminum gallium garnet (GAGG:Ce) scintillators and silicon photomultiplier (SiPM) arrays. Special attention is paid to improving the resolving capability of edge crystals. We propose to place optical barrier (OB) slits onto the light guide that enhances the difference in light distribution for edge crystals. We experimentally optimize OB designs for two scintillator arrays, named as Array-ESR and Array-BaSO4, which uses enhanced specular reflector (ESR) film and barium sulfate (BaSO4) as the reflectors respectively. Both arrays have 31 × 31 0.8 mm × 0.8 mm × 6 mm GAGG:Ce crystals. We introduce the flood map quality (FMQ) parameter to assess the separation of responses of neighboring crystals. The results demonstrate that for Array-ESR, an optimal light guide with two 7° OB slits and two 11° OB slits resolves 92.40 % crystals with an energy resolution of 13.19 ± 0.68%. The FMQ is 1.52 ± 0.38. For Array-BaSO4, the optimal design is a light guide with four 7° OB slits. 98.75 % crystals are resolvable with an energy resolution of 15.33 ± 0.96 % and FMQ parameter of 1.81 ± 0.45. Overall, Array-BaSO4 is more suitable for building SPECT detector for its good crystal resolving performance and fabrication convenience. This study proposes a practical sub-millimeter pixelated SPECT detector design with no detection dead space and compact electronics. It is promising for being used to build largescale detectors for high resolution SPECT systems.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-04-09
DOI
https://doi.org/10.1109/trpms.2025.3559095
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Submillimeter Pixelated SPECT Detector Using GAGG:Ce and Light Guide With Optical Barrier Slits

Zhenlei Lyu, Tianyu Ma, Jing Wu, Zerui Yu et al.
1 citations
IEEE Transactions on Radiation and Plasma Medical Sciences
Medical Imaging Techniques and Applications
1.36
article

Submillimeter Pixelated SPECT Detector Using GAGG:Ce and Light Guide With Optical Barrier Slits

Zhenlei Lyu, Tianyu Ma, Jing Wu, Zerui Yu, Yaqiang Liu, Penglong Fan
article en
1 citations

Abstract

In nuclear medicine imaging systems, intrinsic spatial resolution of the detector is one of the most important performance metrics. In this work, we aim to develop a high-resolution single photon emission computed tomography (SPECT) detector using pixelated Cedoped gadolinium aluminum gallium garnet (GAGG:Ce) scintillators and silicon photomultiplier (SiPM) arrays. Special attention is paid to improving the resolving capability of edge crystals. We propose to place optical barrier (OB) slits onto the light guide that enhances the difference in light distribution for edge crystals. We experimentally optimize OB designs for two scintillator arrays, named as Array-ESR and Array-BaSO4, which uses enhanced specular reflector (ESR) film and barium sulfate (BaSO4) as the reflectors respectively. Both arrays have 31 × 31 0.8 mm × 0.8 mm × 6 mm GAGG:Ce crystals. We introduce the flood map quality (FMQ) parameter to assess the separation of responses of neighboring crystals. The results demonstrate that for Array-ESR, an optimal light guide with two 7° OB slits and two 11° OB slits resolves 92.40 % crystals with an energy resolution of 13.19 ± 0.68%. The FMQ is 1.52 ± 0.38. For Array-BaSO4, the optimal design is a light guide with four 7° OB slits. 98.75 % crystals are resolvable with an energy resolution of 15.33 ± 0.96 % and FMQ parameter of 1.81 ± 0.45. Overall, Array-BaSO4 is more suitable for building SPECT detector for its good crystal resolving performance and fabrication convenience. This study proposes a practical sub-millimeter pixelated SPECT detector design with no detection dead space and compact electronics. It is promising for being used to build largescale detectors for high resolution SPECT systems.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 9(8)
China Academy of Space Technology (CN), Beijing Normal University (CN), Tsinghua University (CN)
Beijing Municipal Natural Science Foundation
Affordable and clean energy
Openalex Percentile: Top 22%
Medical Imaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.