A Novel Localized Coherence Rule Delay-and-Multiply Algorithm Toward Long-Range Ultrasound Imaging With Narrow Field-of-View pMUTs

This work proposes an innovative signal post-processing algorithm for long-range ultrasound imaging by using a narrow Field-of-View (narrow-FoV) Lead Zirconate Titanate (PZT) piezoelectric Micromachined Utrasonic Transducer (pMUT) array. Two 3×3 mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> dies of a 1D-array pMUT, whose resonant frequency is 6.5 MHz, consisting of 18-channels, were employed for this demonstration. The entire system has 18-channels by electrically combining two columns of pMUT membranes as one to increase the transmission power with the cost of narrowing FoV. In this work, experimental testing using single and multiple 5 mm diameter spherical reflectors at various arrangements was performed to validate the 2D imaging capabilities of the developed pMUT array with the proposed image reconstruction algorithm achieving a 1.5 mm lateral resolution.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-09
DOI
https://doi.org/10.1109/jsen.2025.3557576
Citations
3
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Localized Coherence Rule Delay-and-Multiply Algorithm Toward Long-Range Ultrasound Imaging With Narrow Field-of-View pMUTs

Yul Koh, David Sze Wai Choong, Duan Jian Goh, Mantalena Sarafianou et al.
3 citations
IEEE Sensors Journal
Photoacoustic and Ultrasonic Imaging
2.02
article

A Novel Localized Coherence Rule Delay-and-Multiply Algorithm Toward Long-Range Ultrasound Imaging With Narrow Field-of-View pMUTs

Yul Koh, David Sze Wai Choong, Duan Jian Goh, Mantalena Sarafianou, Gaia Giubilei
article en
3 citations

Abstract

This work proposes an innovative signal post-processing algorithm for long-range ultrasound imaging by using a narrow Field-of-View (narrow-FoV) Lead Zirconate Titanate (PZT) piezoelectric Micromachined Utrasonic Transducer (pMUT) array. Two 3×3 mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> dies of a 1D-array pMUT, whose resonant frequency is 6.5 MHz, consisting of 18-channels, were employed for this demonstration. The entire system has 18-channels by electrically combining two columns of pMUT membranes as one to increase the transmission power with the cost of narrowing FoV. In this work, experimental testing using single and multiple 5 mm diameter spherical reflectors at various arrangements was performed to validate the 2D imaging capabilities of the developed pMUT array with the proposed image reconstruction algorithm achieving a 1.5 mm lateral resolution.

IEEE Sensors JournalVol. 25(10)
Agency for Science, Technology and Research (SG), Politecnico di Torino (IT), Institute of Microelectronics (SG), A*STAR Graduate Academy (SG)
Openalex Percentile: Top 15%
Photoacoustic and Ultrasonic Imaging
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.