Improving Representation of High-Frequency Components for Medical Visual Foundation Models

Foundation models have attracted significant attention for their impressive generalizability across diverse downstream tasks. However, they are demonstrated to exhibit great limitations in representing high-frequency components and fine-grained details. In many medical imaging tasks, precise representation of such information is crucial due to the inherently intricate anatomical structures, sub-visual features, and complex boundaries involved. Consequently, the limited representation of prevalent foundation models can result in considerable performance degradation or even failure in these tasks. To address these challenges, we propose a novel pretraining strategy for both 2D images and 3D volumes, named Frequency-advanced Representation Autoencoder (Frepa). Through high-frequency masking and low-frequency perturbation combined with embedding consistency learning, Frepa encourages the encoder to effectively represent and preserve high-frequency components in the image embeddings. Additionally, we introduce an innovative histogram-equalized image masking strategy, extending the Masked Autoencoder approach beyond ViT to other architectures such as Swin-Transformer and convolutional networks. We develop Frepa across nine medical modalities and validate it on 32 downstream tasks for both 2D images and 3D volumes. Without fine-tuning, Frepa can outperform other self-supervised pretraining methods and, in some cases, even surpasses task-specific foundation models. This improvement is particularly significant for tasks involving fine-grained details, such as achieving up to a +15% increase in dice score for retina vessel segmentation and a +8% increase in IoU for lung tumor detection. Further experiment quantitatively reveals that Frepa enables superior high-frequency representations and preservation in the embeddings, underscoring its potential for developing more generalized and universal medical image foundation models.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2025-04-09
DOI
https://doi.org/10.1109/tmi.2025.3559402
Citations
4
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
9.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Representation of High-Frequency Components for Medical Visual Foundation Models

Chao Huang, Longxi Zhou, Zhongyi Han, Gongning Luo et al.
4 citations
IEEE Transactions on Medical Imaging
AI in cancer detection
9.92
article

Improving Representation of High-Frequency Components for Medical Visual Foundation Models

Chao Huang, Longxi Zhou, Zhongyi Han, Gongning Luo, Xin D. Gao, Yilan Zhang, Changchun Yang, Yuetan Chu
article en
4 citations

Abstract

Foundation models have attracted significant attention for their impressive generalizability across diverse downstream tasks. However, they are demonstrated to exhibit great limitations in representing high-frequency components and fine-grained details. In many medical imaging tasks, precise representation of such information is crucial due to the inherently intricate anatomical structures, sub-visual features, and complex boundaries involved. Consequently, the limited representation of prevalent foundation models can result in considerable performance degradation or even failure in these tasks. To address these challenges, we propose a novel pretraining strategy for both 2D images and 3D volumes, named Frequency-advanced Representation Autoencoder (Frepa). Through high-frequency masking and low-frequency perturbation combined with embedding consistency learning, Frepa encourages the encoder to effectively represent and preserve high-frequency components in the image embeddings. Additionally, we introduce an innovative histogram-equalized image masking strategy, extending the Masked Autoencoder approach beyond ViT to other architectures such as Swin-Transformer and convolutional networks. We develop Frepa across nine medical modalities and validate it on 32 downstream tasks for both 2D images and 3D volumes. Without fine-tuning, Frepa can outperform other self-supervised pretraining methods and, in some cases, even surpasses task-specific foundation models. This improvement is particularly significant for tasks involving fine-grained details, such as achieving up to a +15% increase in dice score for retina vessel segmentation and a +8% increase in IoU for lung tumor detection. Further experiment quantitatively reveals that Frepa enables superior high-frequency representations and preservation in the embeddings, underscoring its potential for developing more generalized and universal medical image foundation models.

IEEE Transactions on Medical ImagingVol. 44(8)
Chinese Academy of Sciences (CN), Ningbo Institute of Industrial Technology (CN), King Abdullah University of Science and Technology (SA)
Openalex Percentile: Top 2%
AI in cancer detection
9.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.