The increasing prevalence of musculoskeletal disorders necessitates the development of precise and user-friendly tools in physiotherapy to improve rehabilitation outcomes. Traditional methods for determining the Angle of Pull (AOP) and locating resistance points in clinical settings often lack accuracy and accessibility. To address this issue, this study introduces the Angle Assist (A²) device, aimed at enhancing the precision and effectiveness of rehabilitation exercises by accurately identifying the resistance point where the line of pull generates maximal muscle torque. The primary objective of this research was to design and develop a prototype for an AOP resistor point locator equipped with a precise angle reading display, aimed at reducing the time required to determine the AOP and pinpoint the resistance point by at least 10%. The methodology involved the integration of an MPU6050 sensor, an OLED display and laser pointers, all controlled by customized firmware. The device was subjected to a series of tests, including accuracy, reliability and time improvement test. The results demonstrate that the A² device achieves high accuracy, with an R² value of 0.9991 when compared to true angles. Additionally, the device exceeded the initial objective by reducing the time required to determine the AOP and pinpoint the resistance point by 16.92%. In conclusion, the A² device represents a significant advancement in physiotherapy practices by providing precise angle measurements and improving the accuracy of resistance point placement.

Authors

Institutions

Publication Details

Journal
Semarak International Journal of Public Health and Primary Care
Published
2025-04-09
DOI
https://doi.org/10.37934/sijphpc.3.1.8196
Primary Topic
Network Time Synchronization Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Angle-of-Pull (AOP) Resistor Point Locator Prototype for Application in Physiotherapy

Rabiatul Adawiah Abdul Rahman, Syamimi Shamsuddin, L. Hong, Ahmad Syazwan Ahmad Kamal et al.
Semarak International Journal of Public Health and Primary Care
Network Time Synchronization Technologies
article

Angle-of-Pull (AOP) Resistor Point Locator Prototype for Application in Physiotherapy

Rabiatul Adawiah Abdul Rahman, Syamimi Shamsuddin, L. Hong, Ahmad Syazwan Ahmad Kamal, Bahman Jamaluddin
article en

Abstract

The increasing prevalence of musculoskeletal disorders necessitates the development of precise and user-friendly tools in physiotherapy to improve rehabilitation outcomes. Traditional methods for determining the Angle of Pull (AOP) and locating resistance points in clinical settings often lack accuracy and accessibility. To address this issue, this study introduces the Angle Assist (A²) device, aimed at enhancing the precision and effectiveness of rehabilitation exercises by accurately identifying the resistance point where the line of pull generates maximal muscle torque. The primary objective of this research was to design and develop a prototype for an AOP resistor point locator equipped with a precise angle reading display, aimed at reducing the time required to determine the AOP and pinpoint the resistance point by at least 10%. The methodology involved the integration of an MPU6050 sensor, an OLED display and laser pointers, all controlled by customized firmware. The device was subjected to a series of tests, including accuracy, reliability and time improvement test. The results demonstrate that the A² device achieves high accuracy, with an R² value of 0.9991 when compared to true angles. Additionally, the device exceeded the initial objective by reducing the time required to determine the AOP and pinpoint the resistance point by 16.92%. In conclusion, the A² device represents a significant advancement in physiotherapy practices by providing precise angle measurements and improving the accuracy of resistance point placement.

Semarak International Journal of Public Health and Primary CareVol. 3(1)
Universiti Sains Malaysia (MY), Universiti Teknologi MARA (MY)
Openalex Percentile: Top 93%
Network Time Synchronization Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.