A Novel Hybrid Event‐Based System Separation and Response‐Driven Under‐Frequency Load Shedding Scheme in a Standalone Power System With Renewables

ABSTRACT The increasing integration of renewable energy sources into power systems, driven by their clean and sustainable attributes, has attracted significant attention. However, during severe contingency events, renewable resources such as photovoltaics (PV) may trip prematurely due to their own protection strategies, potentially occurring before load shedding and leading to cascading outages. This paper presents a novel hybrid special protection scheme (SPS) for autonomous (standalone) power systems with renewables. The proposed approach combines an event‐based system separation strategy with a response‐driven under‐frequency load shedding (UFLS) strategy to mitigate premature renewables tripping, thereby preventing catastrophic cascading load shedding. Hybrid particle swarm optimization is employed to determine the optimal splitting points in the power system. Additionally, the total shed loads at all steps of 81L relays in the separated areas are minimized, while the average frequency nadir across all separated areas is maximized. The uncertainty in PV power generation is modeled using probabilistic methods to account for various scenarios. The effectiveness of the proposed method is demonstrated using a 31‐bus standalone power grid with a total demand of 66.62 MW and PV power generation of 7.61 MW. The results show that the proposed method sheds only 11.30 MW of load and trips 2.18 MW of PV power generation, compared to 25.28 MW of load shedding and 6.47 MW of PV tripping observed in existing methods under high irradiance conditions.

Authors

Institutions

Publication Details

Journal
IET Generation Transmission & Distribution
Published
2025-01-01
DOI
https://doi.org/10.1049/gtd2.70054
Citations
1
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Hybrid Event‐Based System Separation and Response‐Driven Under‐Frequency Load Shedding Scheme in a Standalone Power System With Renewables

Ying‐Yi Hong, H.-M. Huang
1 citations
IET Generation Transmission & Distribution
Power System Optimization and Stability
0.73
article

A Novel Hybrid Event‐Based System Separation and Response‐Driven Under‐Frequency Load Shedding Scheme in a Standalone Power System With Renewables

Ying‐Yi Hong, H.-M. Huang
article en
1 citations

Abstract

ABSTRACT The increasing integration of renewable energy sources into power systems, driven by their clean and sustainable attributes, has attracted significant attention. However, during severe contingency events, renewable resources such as photovoltaics (PV) may trip prematurely due to their own protection strategies, potentially occurring before load shedding and leading to cascading outages. This paper presents a novel hybrid special protection scheme (SPS) for autonomous (standalone) power systems with renewables. The proposed approach combines an event‐based system separation strategy with a response‐driven under‐frequency load shedding (UFLS) strategy to mitigate premature renewables tripping, thereby preventing catastrophic cascading load shedding. Hybrid particle swarm optimization is employed to determine the optimal splitting points in the power system. Additionally, the total shed loads at all steps of 81L relays in the separated areas are minimized, while the average frequency nadir across all separated areas is maximized. The uncertainty in PV power generation is modeled using probabilistic methods to account for various scenarios. The effectiveness of the proposed method is demonstrated using a 31‐bus standalone power grid with a total demand of 66.62 MW and PV power generation of 7.61 MW. The results show that the proposed method sheds only 11.30 MW of load and trips 2.18 MW of PV power generation, compared to 25.28 MW of load shedding and 6.47 MW of PV tripping observed in existing methods under high irradiance conditions.

IET Generation Transmission & DistributionVol. 19(1)
Chung Yuan Christian University (TW)
National Science and Technology Council
Openalex Percentile: Top 30%
Power System Optimization and Stability
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Hybrid Event‐Based System Separation and Response‐Driven Under‐Frequency Load Shedding Scheme in a Standalone Power System With Renewables — Ying‐Yi Hong, H.-M. Huang · IET Generation Transmission & Distribution (2025) | TGRS Research Map | TGRS