An innovative deep learning-driven technique for restoration of lost high-density surface electromyography signals

Abstract High-density surface electromyography (HD-sEMG) plays a crucial role in medical diagnostics, prosthetic control, and human-machine interactions. Compared to traditional bipolar sEMG, HD-sEMG employs smaller electrode spacing and sizes. This configuration not only reduces the signal collection area but also increases sensitivity to individual variations in skin impedance. Additionally, smaller high-density electrodes are more susceptible to environmental electromagnetic interference, thereby increasing the risk of signal loss and limiting the further development and application of HD-sEMG technology. To address this issue, this study introduces a novel deep learning-based technique specifically designed to restore lost HD-sEMG signals. Through an improved novel convolutional neural network (CNN), our method can reconstruct HD-sEMG signals both efficiently and accurately. Experimental results demonstrate that the proposed CNN algorithm effectively reconstructs lost HD-sEMG signals with high fidelity. The average root mean square error (RMSE) across all participants was 0.108, the mean absolute error (MAE) was 0.070, and the coefficient of determination ( $$R^2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mi>R</mml:mi> <mml:mn>2</mml:mn> </mml:msup> </mml:math> ) was 0.98. Furthermore, the model achieved an average structural similarity index measure (SSIM) of 0.96 and a peak signal-to-noise ratio (PSNR) of 29.13 dB, indicating high levels of structural similarity and signal clarity in the reconstructed data. These findings highlight the robustness and effectiveness of our method, suggesting its potential for enhancing the reliability and utility of HD-sEMG signals in real applications.

Authors

Institutions

Publication Details

Journal
Applied Intelligence
Published
2025-04-08
DOI
https://doi.org/10.1007/s10489-025-06471-9
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An innovative deep learning-driven technique for restoration of lost high-density surface electromyography signals

Yongkun Zhao, Honghan Li, Juzheng Mao
Applied Intelligence
Muscle activation and electromyography studies
article

An innovative deep learning-driven technique for restoration of lost high-density surface electromyography signals

Yongkun Zhao, Honghan Li, Juzheng Mao
article en

Abstract

Abstract High-density surface electromyography (HD-sEMG) plays a crucial role in medical diagnostics, prosthetic control, and human-machine interactions. Compared to traditional bipolar sEMG, HD-sEMG employs smaller electrode spacing and sizes. This configuration not only reduces the signal collection area but also increases sensitivity to individual variations in skin impedance. Additionally, smaller high-density electrodes are more susceptible to environmental electromagnetic interference, thereby increasing the risk of signal loss and limiting the further development and application of HD-sEMG technology. To address this issue, this study introduces a novel deep learning-based technique specifically designed to restore lost HD-sEMG signals. Through an improved novel convolutional neural network (CNN), our method can reconstruct HD-sEMG signals both efficiently and accurately. Experimental results demonstrate that the proposed CNN algorithm effectively reconstructs lost HD-sEMG signals with high fidelity. The average root mean square error (RMSE) across all participants was 0.108, the mean absolute error (MAE) was 0.070, and the coefficient of determination ( $$R^2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mi>R</mml:mi> <mml:mn>2</mml:mn> </mml:msup> </mml:math> ) was 0.98. Furthermore, the model achieved an average structural similarity index measure (SSIM) of 0.96 and a peak signal-to-noise ratio (PSNR) of 29.13 dB, indicating high levels of structural similarity and signal clarity in the reconstructed data. These findings highlight the robustness and effectiveness of our method, suggesting its potential for enhancing the reliability and utility of HD-sEMG signals in real applications.

Applied IntelligenceVol. 55(7)
University of Science and Technology Liaoning (CN), Southeast University (BD), Imperial College London (GB), Southeast University (CN)
Japan Society for the Promotion of Science
Openalex Percentile: Top 93%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.