QBD Driven Bioanalytical Method Development and Validation of Tepotinib using RP-UPLC

The research aims to establish a new UPLC method for estimating Tepotinib in human plasma.A simple, precise, and accurate RP-UPLC technique has been developed to quantify Tepotinib (TEP) in human plasma by employing a Quality by Design (QbD) approach.The effective separation of TEP was accomplished using the ACQUITY UPLC HSS C18 Column (1.8 m, 2.1 mm100 mm) and 0.01N Ammonium formate : Methanol in 70:30 v/v delivered at a flow rate of 0.3ml/min.The eluted TEP and internal standard Linagliptin (LIN) were detected at 258nm wavelength with good resolution.A temperature of 30 0 C is maintained in the column throughout the experimental study.Equal volumes of methanol and water are considered as diluent to prepare the standard stock, working standard, and quality control sample solutions.TEP and LIN were eluted at 2.023 min, and 1.668 min, respectively, achieving a resolution of 4.3.The standard curve was linear (r 2 =0.999) across the 8-320 ng/ml concentration range of TEP.The validated method exhibited satisfactory performance aligning with ICH guidelines.The robustness and suitability of the method were further authenticated through QbD studies, making it compatible with therapeutic drug monitoring and determining the pharmacokinetic profile of TEP in In-Vivo studies.

Authors

Publication Details

Journal
International Journal of Advanced Science and Engineering
Published
2025-03-29
DOI
https://doi.org/10.29294/ijase.11.3.2025.4223-4236
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QBD Driven Bioanalytical Method Development and Validation of Tepotinib using RP-UPLC

Bonagiri Pavani, Narender Malothu, Anka Rao Areti, Chakravarthi Guntupalli
International Journal of Advanced Science and Engineering
Analytical Methods in Pharmaceuticals
article

QBD Driven Bioanalytical Method Development and Validation of Tepotinib using RP-UPLC

Bonagiri Pavani, Narender Malothu, Anka Rao Areti, Chakravarthi Guntupalli
article en

Abstract

The research aims to establish a new UPLC method for estimating Tepotinib in human plasma.A simple, precise, and accurate RP-UPLC technique has been developed to quantify Tepotinib (TEP) in human plasma by employing a Quality by Design (QbD) approach.The effective separation of TEP was accomplished using the ACQUITY UPLC HSS C18 Column (1.8 m, 2.1 mm100 mm) and 0.01N Ammonium formate : Methanol in 70:30 v/v delivered at a flow rate of 0.3ml/min.The eluted TEP and internal standard Linagliptin (LIN) were detected at 258nm wavelength with good resolution.A temperature of 30 0 C is maintained in the column throughout the experimental study.Equal volumes of methanol and water are considered as diluent to prepare the standard stock, working standard, and quality control sample solutions.TEP and LIN were eluted at 2.023 min, and 1.668 min, respectively, achieving a resolution of 4.3.The standard curve was linear (r 2 =0.999) across the 8-320 ng/ml concentration range of TEP.The validated method exhibited satisfactory performance aligning with ICH guidelines.The robustness and suitability of the method were further authenticated through QbD studies, making it compatible with therapeutic drug monitoring and determining the pharmacokinetic profile of TEP in In-Vivo studies.

International Journal of Advanced Science and EngineeringVol. 11(3)
Openalex Percentile: Top 92%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.