QUALITY CONTROL TESTS FOR CALIBRATION OF KAP METERS.

In accordance with IEC 60580:2021, KAP meters are typically calibrated using cylindrical reference ionization chambers aligned with RQR radiation qualities specified by ISO 61267. However, discrepancies in manufacturing geometry between these reference chambers and PKA meters prompted a series of quality control tests to establish an effective calibration methodology. Two distinct tests of quality control were conducted to compare the performance of a reference KAP meter (PDC - Radcal®) with a reference ionization chamber (Radcal® 10x5-180), using the Agfa® PANTAK Constant Potential X-Ray System. These tests included homogeneity assessments with varying horizontal displacements of the reference PDC meter and reproducibility tests at consistent positions. The two tests were conducted for Kerma and PKA unities. A third test is still in progress, the long-term stability, with repeated measurements; as with the tests ago, for Kerma and KAP measurements. These results demonstrated good correlation and traceability between the PDC and the ionization chamber, with reproducibility and homogeneity within an uncertainty margin below 3 %. These findings validate the proposed calibration method for practical applications.

Authors

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2025-04-09
DOI
https://doi.org/10.15392/2319-0612.2024.2687
Citations
1
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
1.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QUALITY CONTROL TESTS FOR CALIBRATION OF KAP METERS.

M.P.A. Potiens, José Neres de Almeida, Orlando Rodrigues
1 citations
Brazilian Journal of Radiation Sciences
Scientific Measurement and Uncertainty Evaluation
1.40
article

QUALITY CONTROL TESTS FOR CALIBRATION OF KAP METERS.

M.P.A. Potiens, José Neres de Almeida, Orlando Rodrigues
article en
1 citations

Abstract

In accordance with IEC 60580:2021, KAP meters are typically calibrated using cylindrical reference ionization chambers aligned with RQR radiation qualities specified by ISO 61267. However, discrepancies in manufacturing geometry between these reference chambers and PKA meters prompted a series of quality control tests to establish an effective calibration methodology. Two distinct tests of quality control were conducted to compare the performance of a reference KAP meter (PDC - Radcal®) with a reference ionization chamber (Radcal® 10x5-180), using the Agfa® PANTAK Constant Potential X-Ray System. These tests included homogeneity assessments with varying horizontal displacements of the reference PDC meter and reproducibility tests at consistent positions. The two tests were conducted for Kerma and PKA unities. A third test is still in progress, the long-term stability, with repeated measurements; as with the tests ago, for Kerma and KAP measurements. These results demonstrated good correlation and traceability between the PDC and the ionization chamber, with reproducibility and homogeneity within an uncertainty margin below 3 %. These findings validate the proposed calibration method for practical applications.

Brazilian Journal of Radiation SciencesVol. 12(4B (Suppl.))
Openalex Percentile: Top 17%
Scientific Measurement and Uncertainty Evaluation
1.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.