Coordinated control strategy of hydrogen production system in DC microgrid considering operating states of electrolyzer

Abstract The utilization of clean energy for hydrogen production is a critical approach to reducing carbon emissions and efficiently absorbing renewable power generation. For off-grid water electrolysis hydrogen production, a coordinated control strategy for ‘wind-storage-hydrogen’ DC microgrid is proposed in present work, accounting for the wide power range of the electrolyzer. This strategy addresses issues of system instability and suboptimal power distribution caused by wind power fluctuations and variations of electrolyzer states. Firstly, the structure of the DC microgrid hydrogen production system is defined, and operating modes are segmented based on bus voltage to enable coordinated operation among the ‘wind-storage-hydrogen’. Secondly, an adaptive fuzzy droop control is introduced, dynamically adjusting the slope and endpoints of the droop curve according to the electrolyzer’s key states and operating characteristics. This achieves adaptive responses to electrolyzer state changes across different load range. Then, a coordination sub-strategy for ‘storage-hydrogen’ is designed based on bus voltage deviation, which suppresses bus voltage fluctuations and ensures efficient electrolyzer operation by optimizing energy distribution between energy storage and hydrogen production during trough period. The simulation results indicate that the stability of the system bus voltage and electrolyzer operation is improved significantly. Additionally, the power distribution scheme is optimized. When the electrolyzer operates under low-load conditions, it can achieve a 9.6% increase in its efficiency while maintaining voltage deviation below 4.2%.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2025-04-09
DOI
https://doi.org/10.1088/2631-8695/adcb02
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coordinated control strategy of hydrogen production system in DC microgrid considering operating states of electrolyzer

Mingxuan Chen, Baoping Zhang, Yunhe Hou, Yuan Jiang et al.
Engineering Research Express
Hybrid Renewable Energy Systems
article

Coordinated control strategy of hydrogen production system in DC microgrid considering operating states of electrolyzer

Mingxuan Chen, Baoping Zhang, Yunhe Hou, Yuan Jiang, Wenzhen Chen
article en

Abstract

Abstract The utilization of clean energy for hydrogen production is a critical approach to reducing carbon emissions and efficiently absorbing renewable power generation. For off-grid water electrolysis hydrogen production, a coordinated control strategy for ‘wind-storage-hydrogen’ DC microgrid is proposed in present work, accounting for the wide power range of the electrolyzer. This strategy addresses issues of system instability and suboptimal power distribution caused by wind power fluctuations and variations of electrolyzer states. Firstly, the structure of the DC microgrid hydrogen production system is defined, and operating modes are segmented based on bus voltage to enable coordinated operation among the ‘wind-storage-hydrogen’. Secondly, an adaptive fuzzy droop control is introduced, dynamically adjusting the slope and endpoints of the droop curve according to the electrolyzer’s key states and operating characteristics. This achieves adaptive responses to electrolyzer state changes across different load range. Then, a coordination sub-strategy for ‘storage-hydrogen’ is designed based on bus voltage deviation, which suppresses bus voltage fluctuations and ensures efficient electrolyzer operation by optimizing energy distribution between energy storage and hydrogen production during trough period. The simulation results indicate that the stability of the system bus voltage and electrolyzer operation is improved significantly. Additionally, the power distribution scheme is optimized. When the electrolyzer operates under low-load conditions, it can achieve a 9.6% increase in its efficiency while maintaining voltage deviation below 4.2%.

Engineering Research ExpressVol. 7(2)
University of Liverpool (GB), China Three Gorges Corporation (China) (CN), Beijing Information Science & Technology University (CN), University of Hong Kong (HK)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 95%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.