Microwave stray radiation measurement techniques

In magnetic-confinement fusion experiments, such as tokamaks and stellarators, microwave stray radiation loads occur due to non-absorbed electron cyclotron heating power, or – at very high electron temperatures – due to cyclotron emission from the fusion plasma itself. The metallic first wall of the plasma vessel reflects most of the non-absorbed power and generates a more or less homogeneous stray radiation field, which causes ohmic and dielectric heating in lossy components, while in microwave receivers outside the vessel it may cause overload or even destruction of mixers and detectors. These issues are understood and mitigation measures are developed or already in place. However, accurate and fast diagnoses of stray radiation provides a challenge: stray radiation may not be a truly scrambled mixture of k-vectors and polarisation. In such case, the signal of a single-mode microwave detector will show strong fluctuations in time. Bolometers, with a size such that many modes are simultaneously measured, provide a much more stable signal due to the integration, but the time response is of the order of seconds. And an inherent aspect of bolometers is that at elevated temperatures they become non-linear due to radiative heat losses. A caloric measurement, using for instance a water-cooled microwave load, gives a calibrated and reproducible measurement but is very slow — typically several minutes. Due to size and water coolant, calorimetry is challenging to integrate into a fusion experiment. However, it is useful for cross-calibration of bolometers. In this paper microwave stray radiation is briefly introduced, then followed by an overview of measurement techniques in use at the Wendelstein 7-X stellarator (W7-X) as well as development work together with ITER. • Measurement of stray radiation by non-absorbed Electron Cyclotron Resonance Heating. • Generation of diffuse microwave stray radiation. • Construction of a calorimetric microwave load. • Calibration factor of a bolometer with microwave absorbing coating.

Authors

Institutions

Publication Details

Journal
Fusion Engineering and Design
Published
2025-04-09
DOI
https://doi.org/10.1016/j.fusengdes.2025.114967
Citations
1
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microwave stray radiation measurement techniques

S. Pak, M. Hirsch, T. Stange, A. Sirinelli et al.
1 citations
Fusion Engineering and Design
Magnetic confinement fusion research
article

Microwave stray radiation measurement techniques

S. Pak, M. Hirsch, T. Stange, A. Sirinelli, D. Moseev, K. J. Brunner, C. Sozzi, B. Kursinski, R. C. Wolf, M. Stern, A. Moro, S. Marsen, H. P. Laqua, Rafael J. Zubieta-Lupo, J. W. Oosterbeek
article en
1 citations

Abstract

In magnetic-confinement fusion experiments, such as tokamaks and stellarators, microwave stray radiation loads occur due to non-absorbed electron cyclotron heating power, or – at very high electron temperatures – due to cyclotron emission from the fusion plasma itself. The metallic first wall of the plasma vessel reflects most of the non-absorbed power and generates a more or less homogeneous stray radiation field, which causes ohmic and dielectric heating in lossy components, while in microwave receivers outside the vessel it may cause overload or even destruction of mixers and detectors. These issues are understood and mitigation measures are developed or already in place. However, accurate and fast diagnoses of stray radiation provides a challenge: stray radiation may not be a truly scrambled mixture of k-vectors and polarisation. In such case, the signal of a single-mode microwave detector will show strong fluctuations in time. Bolometers, with a size such that many modes are simultaneously measured, provide a much more stable signal due to the integration, but the time response is of the order of seconds. And an inherent aspect of bolometers is that at elevated temperatures they become non-linear due to radiative heat losses. A caloric measurement, using for instance a water-cooled microwave load, gives a calibrated and reproducible measurement but is very slow — typically several minutes. Due to size and water coolant, calorimetry is challenging to integrate into a fusion experiment. However, it is useful for cross-calibration of bolometers. In this paper microwave stray radiation is briefly introduced, then followed by an overview of measurement techniques in use at the Wendelstein 7-X stellarator (W7-X) as well as development work together with ITER. • Measurement of stray radiation by non-absorbed Electron Cyclotron Resonance Heating. • Generation of diffuse microwave stray radiation. • Construction of a calorimetric microwave load. • Calibration factor of a bolometer with microwave absorbing coating.

Fusion Engineering and DesignVol. 215
ITER (FR), Max Planck Institute for Plasma Physics - Greifswald (DE), Institute for the Science and Technology of Plasmas (IT)
EUROfusion, European Commission
Openalex Percentile: Top 96%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.