Integrated microphotonic platform for highly sensitive virus detection

• Novel ring resonator design with high sensitivity for virus detection. • Operates at 1310 nm to minimize absorption in biological samples. • Demonstrates real-time SARS-CoV-2 detection at picomolar concentrations. • Achieves sub-100 pM limit-of-detection with oriented antibody immobilization. • Suitable for portable, cost-effective point-of-care diagnostics. Chip-scale micro-photonic biosensors have matured significantly over the past two decades, with various platforms developed for detecting biomarkers, including proteins in biological fluids. The COVID-19 pandemic has further accelerated research in virus detection, leading to the development of resonant and interferometric biosensors for identifying viruses like SARS-CoV-2. Despite these advancements, there remains a need for technical solutions that ensure point-of-care features such as low cost, rapid response, and low limit-of-detection (LoD). This paper presents an integrated silicon nitride microphotonic platform based on ring resonator technology, specifically designed for highly sensitive virus detection. The sensors, fabricated using strip and slot waveguides, are tested under flow conditions using ethanol and BSA-antiBSA solutions to evaluate bulk and surface sensitivity. The results indicate that the slot waveguide-based ring resonators exhibit the highest sensitivity. The platform uses functionalization protocols to immobilize specific antibodies for detecting SARS-CoV-2. The sensor successfully identifies the target analyte at concentrations as low as 1.5 nM, with a LoD of 36 pM using in situ functionalization, underscoring the importance of antibody orientation through an intermediate protein A layer. These results demonstrate the platform’s potential for rapid and sensitive virus diagnosis and represent a significant step toward the development of portable, point-of-care diagnostic technologies for infectious disease monitoring.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators Reports
Published
2025-04-09
DOI
https://doi.org/10.1016/j.snr.2025.100320
Citations
1
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated microphotonic platform for highly sensitive virus detection

M Gómez-Gómez, E. Gómez, Francesco Dell’Olio, Annabella la Grasta et al.
1 citations
Sensors and Actuators Reports
Photonic and Optical Devices
0.73
article

Integrated microphotonic platform for highly sensitive virus detection

M Gómez-Gómez, E. Gómez, Francesco Dell’Olio, Annabella la Grasta, Amadeu Griol, Vittorio M. N. Passaro, Alexander A. Martínez, Martino De Carlo
article en
1 citations

Abstract

• Novel ring resonator design with high sensitivity for virus detection. • Operates at 1310 nm to minimize absorption in biological samples. • Demonstrates real-time SARS-CoV-2 detection at picomolar concentrations. • Achieves sub-100 pM limit-of-detection with oriented antibody immobilization. • Suitable for portable, cost-effective point-of-care diagnostics. Chip-scale micro-photonic biosensors have matured significantly over the past two decades, with various platforms developed for detecting biomarkers, including proteins in biological fluids. The COVID-19 pandemic has further accelerated research in virus detection, leading to the development of resonant and interferometric biosensors for identifying viruses like SARS-CoV-2. Despite these advancements, there remains a need for technical solutions that ensure point-of-care features such as low cost, rapid response, and low limit-of-detection (LoD). This paper presents an integrated silicon nitride microphotonic platform based on ring resonator technology, specifically designed for highly sensitive virus detection. The sensors, fabricated using strip and slot waveguides, are tested under flow conditions using ethanol and BSA-antiBSA solutions to evaluate bulk and surface sensitivity. The results indicate that the slot waveguide-based ring resonators exhibit the highest sensitivity. The platform uses functionalization protocols to immobilize specific antibodies for detecting SARS-CoV-2. The sensor successfully identifies the target analyte at concentrations as low as 1.5 nM, with a LoD of 36 pM using in situ functionalization, underscoring the importance of antibody orientation through an intermediate protein A layer. These results demonstrate the platform’s potential for rapid and sensitive virus diagnosis and represent a significant step toward the development of portable, point-of-care diagnostic technologies for infectious disease monitoring.

Sensors and Actuators ReportsVol. 9
Universitat Politècnica de València (ES), Polytechnic University of Bari (IT)
European Commission, HORIZON EUROPE Framework Programme, Conselleria d'Educació, Investigació, Cultura i Esport
Openalex Percentile: Top 30%
Photonic and Optical Devices
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.