Optimising the manufacture of perfluorocarbon nanodroplets through varying sonication parameters

Perfluorocarbon nanodroplets (PFC-NDs) are promising ultrasound-responsive theranostic agents with applications in both diagnostic imaging and drug delivery. The acoustic vaporisation threshold, extravasation potential, and stability of PFC-NDs are all affected by their size. However, methods to ensure reproducible size and concentration during production by sonication are lacking. To address this need, we examined the effect of temperature, sonication time, sonication intensity, PFC concentration and sonicator tip height on ND characteristics. PFC-NDs with a perfluoro-n-pentane (PFP) core and a phospholipid shell were manufactured by probe-sonication. Pulsed sonication was used to maintain the sample temperature below the boiling point of PFP. Median particle diameter was measured using nanoparticle tracking analysis. PFC-ND diameter increased with increasing PFP concentration, with a stronger relationship as sonicator tip height increased. Above 5% v/v PFP, there was a qualitative increase in the number of particles visible by light microscopy. Increasing the sonication duration did not yield a significant change in ND size. A minimum amplitude of 60% was required for mixing to occur, with amplitudes of 80% and 100% resulting in foam production. Sonicator power output was linear with respect to time but differed depending on sample volume, composition, and vessel geometry. This study indicates that controlling the processing parameters can facilitate reproducible manufacturing of PFC-NDs.

Authors

Institutions

Publication Details

Journal
Ultrasonics Sonochemistry
Published
2025-04-09
DOI
https://doi.org/10.1016/j.ultsonch.2025.107332
Citations
1
Primary Topic
Polymer Nanocomposite Synthesis and Irradiation
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimising the manufacture of perfluorocarbon nanodroplets through varying sonication parameters

Dario Carugo, Jeremy S. Webb, Peter Glynne‐Jones, Nicholas D. Evans et al.
1 citations
Ultrasonics Sonochemistry
Polymer Nanocomposite Synthesis and Irradiation
0.61
article

Optimising the manufacture of perfluorocarbon nanodroplets through varying sonication parameters

Dario Carugo, Jeremy S. Webb, Peter Glynne‐Jones, Nicholas D. Evans, Gareth LuTheryn, Peter R. Birkin, Eleanor Stride, Robin M. H. Rumney, Christopher K. Campbell, Kevin C. O'Brien, Dariusz Kosk
article en
1 citations

Abstract

Perfluorocarbon nanodroplets (PFC-NDs) are promising ultrasound-responsive theranostic agents with applications in both diagnostic imaging and drug delivery. The acoustic vaporisation threshold, extravasation potential, and stability of PFC-NDs are all affected by their size. However, methods to ensure reproducible size and concentration during production by sonication are lacking. To address this need, we examined the effect of temperature, sonication time, sonication intensity, PFC concentration and sonicator tip height on ND characteristics. PFC-NDs with a perfluoro-n-pentane (PFP) core and a phospholipid shell were manufactured by probe-sonication. Pulsed sonication was used to maintain the sample temperature below the boiling point of PFP. Median particle diameter was measured using nanoparticle tracking analysis. PFC-ND diameter increased with increasing PFP concentration, with a stronger relationship as sonicator tip height increased. Above 5% v/v PFP, there was a qualitative increase in the number of particles visible by light microscopy. Increasing the sonication duration did not yield a significant change in ND size. A minimum amplitude of 60% was required for mixing to occur, with amplitudes of 80% and 100% resulting in foam production. Sonicator power output was linear with respect to time but differed depending on sample volume, composition, and vessel geometry. This study indicates that controlling the processing parameters can facilitate reproducible manufacturing of PFC-NDs.

Ultrasonics SonochemistryVol. 118
Nuffield Orthopaedic Centre (GB), University of Oxford (GB), University of Southampton (GB), University of Portsmouth (GB)
Openalex Percentile: Top 38%
Polymer Nanocomposite Synthesis and Irradiation
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.