Lifted frequency-domain identification of closed-loop multirate systems: Applied to dual-stage actuator hard disk drives

Frequency-domain representations are crucial for the design and performance evaluation of controllers in multirate systems, specifically to address intersample performance. The aim of this paper is to develop an effective frequency-domain system identification technique for closed-loop multirate systems using solely slow-rate output measurements. By indirect identification of multivariable time-invariant representations through lifting, in combination with local modeling techniques, the multirate system is effectively identified. The developed method is capable of accurate identification of closed-loop multirate systems within a single identification experiment, using fast-rate excitation and inputs, and slow-rate outputs. Finally, the developed framework is validated using a benchmark problem consisting of a multivariable dual-stage actuator from a hard disk drive, demonstrating its applicability and accuracy.

Authors

Institutions

Publication Details

Journal
Mechatronics
Published
2025-04-09
DOI
https://doi.org/10.1016/j.mechatronics.2025.103311
Citations
4
Primary Topic
Iterative Learning Control Systems
Type
article
Field-Weighted Citation Impact
4.86

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lifted frequency-domain identification of closed-loop multirate systems: Applied to dual-stage actuator hard disk drives

Lennart Blanken, Tom Oomen, Max van Haren, Masahiro Mae
4 citations
Mechatronics
Iterative Learning Control Systems
4.86
article

Lifted frequency-domain identification of closed-loop multirate systems: Applied to dual-stage actuator hard disk drives

Lennart Blanken, Tom Oomen, Max van Haren, Masahiro Mae
article en
4 citations

Abstract

Frequency-domain representations are crucial for the design and performance evaluation of controllers in multirate systems, specifically to address intersample performance. The aim of this paper is to develop an effective frequency-domain system identification technique for closed-loop multirate systems using solely slow-rate output measurements. By indirect identification of multivariable time-invariant representations through lifting, in combination with local modeling techniques, the multirate system is effectively identified. The developed method is capable of accurate identification of closed-loop multirate systems within a single identification experiment, using fast-rate excitation and inputs, and slow-rate outputs. Finally, the developed framework is validated using a benchmark problem consisting of a multivariable dual-stage actuator from a hard disk drive, demonstrating its applicability and accuracy.

MechatronicsVol. 108
Tokyo University of Information Sciences (JP), The University of Tokyo (JP), Eindhoven University of Technology (NL), Delft University of Technology (NL)
European Commission, Electronic Components and Systems for European Leadership, Horizon 2020, H2020 LEIT Information and Communication Technologies
Affordable and clean energy
Openalex Percentile: Top 5%
Iterative Learning Control Systems
4.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lifted frequency-domain identification of closed-loop multirate systems: Applied to dual-stage actuator hard disk drives — Lennart Blanken, Tom Oomen, et al. · Mechatronics (2025) | TGRS Research Map | TGRS