Is IMU- alternative to GRF-based posturography? A comparative assessment on young healthy adults

The measurement of CoP trajectory has become the de-facto standard for posturography. However, in recent years, inertial sensors have been proposed as a portable alternative to force plates. Although their demonstrated potential, the functional interpretation of these methods remains limited, and no standard approach exists for inertial signal processing. This work aims to analyse and compare GRF- and IMU-based metrics (obtained from a single IMU positioned on the trunk at L5 level) in characterising postural control performance in 21 healthy participants on varying surface (i.e. solid ground and three foams of different stiffness) and visual (eyes open/closed) conditions, concurrently analysing how results are affected by different filtering cut-off frequencies. In line with existing literature, GRF signals were lowpass-filtered at 10 Hz, while IMU signals at 0.5 Hz, 3.5 Hz, 5 Hz (i.e. band-width containing 95 % of the signal power), and 10 Hz. Time- and frequency-domain postural parameters were extracted from GRF and IMU signals. Correlations between GRF- and IMU-based metrics resulted weak to moderate (0<|ρ|<0.7). Both GRF- and IMU-based metrics showed increased postural oscillations on foam surfaces, but opposite behaviours in frequency, with no significant difference among different foam types. GRF-based metrics highlighted higher postural oscillations under eyes-closed conditions, especially on foam, whereas IMU-based metrics showed no significant change except for range and root mean square displacement in the medio-lateral direction that decreased with eyes closed (e.g., 5 Hz low pass filtered IMU signal: on foam, median root mean square, with eyes open [25th-75th], 0.08 [0.05-0.12]; with eyes closed, 0.04 [0.03-0.06]). Although describing the same behaviour, GRF- and IMU-based metrics capture different aspects of postural control: based on the inverted pendulum model, GRF-based metrics describe the postural adjustments, while IMU-based ones the postural performance.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-04-09
DOI
https://doi.org/10.1016/j.jbiomech.2025.112687
Citations
2
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
9.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is IMU- alternative to GRF-based posturography? A comparative assessment on young healthy adults

Maria Cristina Bisi, Rita Stagni
2 citations
Journal of Biomechanics
Balance, Gait, and Falls Prevention
9.52
article

Is IMU- alternative to GRF-based posturography? A comparative assessment on young healthy adults

Maria Cristina Bisi, Rita Stagni
article en
2 citations

Abstract

The measurement of CoP trajectory has become the de-facto standard for posturography. However, in recent years, inertial sensors have been proposed as a portable alternative to force plates. Although their demonstrated potential, the functional interpretation of these methods remains limited, and no standard approach exists for inertial signal processing. This work aims to analyse and compare GRF- and IMU-based metrics (obtained from a single IMU positioned on the trunk at L5 level) in characterising postural control performance in 21 healthy participants on varying surface (i.e. solid ground and three foams of different stiffness) and visual (eyes open/closed) conditions, concurrently analysing how results are affected by different filtering cut-off frequencies. In line with existing literature, GRF signals were lowpass-filtered at 10 Hz, while IMU signals at 0.5 Hz, 3.5 Hz, 5 Hz (i.e. band-width containing 95 % of the signal power), and 10 Hz. Time- and frequency-domain postural parameters were extracted from GRF and IMU signals. Correlations between GRF- and IMU-based metrics resulted weak to moderate (0<|ρ|<0.7). Both GRF- and IMU-based metrics showed increased postural oscillations on foam surfaces, but opposite behaviours in frequency, with no significant difference among different foam types. GRF-based metrics highlighted higher postural oscillations under eyes-closed conditions, especially on foam, whereas IMU-based metrics showed no significant change except for range and root mean square displacement in the medio-lateral direction that decreased with eyes closed (e.g., 5 Hz low pass filtered IMU signal: on foam, median root mean square, with eyes open [25th-75th], 0.08 [0.05-0.12]; with eyes closed, 0.04 [0.03-0.06]). Although describing the same behaviour, GRF- and IMU-based metrics capture different aspects of postural control: based on the inverted pendulum model, GRF-based metrics describe the postural adjustments, while IMU-based ones the postural performance.

Journal of BiomechanicsVol. 185
Laboratori Guglielmo Marconi (Italy) (IT), University of Bologna (IT)
Zero hunger
Openalex Percentile: Top 3%
Balance, Gait, and Falls Prevention
9.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.